Operating Instructions
5.3
Versions with manometer
WARNING!
Leakage at pressure gauge outlet!
Risk of material damage and/or injury due to leakage at the pressure gauge outlet for versions with and without adapter.
The pressure gauge bore is drilled at the factory and fitted with a protective plug. Pressure gauge is shipped separately for transport
protection.
► Make sure that the pressure gauge is mounted before commissioning.
WARNING!
Do not adjust the pressure gauge!
Risk of material damage and/or injury due to modification of pressure gauge! Valid for versions with adapter. Pressure gauge is in-
stalled, preset and tested at the factory.
► Do not make any modifications to the pressure gauge.
► Only turn the adapter.
► Do not damage the seal label.
1.
Valve with protective plug at mano-
meter outlet.
2.
Install O-ring at manometer/adap-
tor.
3.
Remove covering cap and turn the
manometer with/without adaptor
with threaded connection into the
valve base part.
4.
Turn
in
manometer/manometer
with adaptor from contact, at least
180° up to max. 360° (align scale).
Manometer
Pressure Regulating Valves Type 582/586
Manometer with adaptor
17