PRODUCT SPECIFICATIONS

Speeds ............................................Hi - 1,400 r/min. (RPM)
Airflow (cubic feet per minute) .....................Hi - 1,437 CFM
INSTALLATION
BEFORE YOU BEGIN
WARNING:
To reduce the risk of fire, electric shock, or
personal injury, turn off power to room and
wall switch by removing fuses or turning off
circuit breakers as needed before beginning
installation.
WARNING:
Mount fan only to a metal outlet box marked
acceptable for fan support and use only the
mounting screws provided with the outlet box.
Plastic outlet boxes and outlet boxes commonly
used for the support of lighting fixtures may not
be acceptable for fan support and may need to
be replaced. If you are unsure whether your outlet
box is appropriate or uncertain about the proper
method for mounting your ceiling fan, contact a
qualified electrician.
Med - 940 r/min. (RPM)
Low - 500 r/min. (RPM)
Med - 830 CFM
Low - 445 CFM
6 - English
Input ......................120 V, AC only, 60 Hz, 0.61 Amps Max.
Net Weight ................................................... approx. 24 lbs.
Ceiling Clearance Distance ......................................10.4 in.
Ceiling Mount Options............................. Angled, Standard
 If your installation site does not have an existing UL-listed
metal outlet box, one must be installed before proceed-
ing. Make sure box is mounted directly to the building
structure using ceiling joist screws provided with the box.
 Once installed, there must be at least 7 ft. clearance
between the bottom of the ceiling fan and the floor.
 Ceilings taller than 8 ft. may benefit from an extended-
length downrod (not included) to achieve the best results.
NOTE: Extended-length downrods longer than 48 in. will
also require a downrod wire extension kit (not included,
available from the retailer where you purchased your fan).
 Angled ceilings must not be steeper than 30˚ from the
horizontal canopy.