TROUBLESHOOTING HINTS

Nothing operates.
Check that the voltage between the + and - terminals of the converter is between 17.5 to
18.5Vc.c., if not, check the power supply and its connections.
Connect a T-700 telephone (or equivalent) to the converter's 4+n connection block and
check that it works correctly.
If it does, then check the configuration of the unit that is connected to the 4+n connection
block.
If it does not, check that the programming has been done correctly. Reprogram it if necessary.
Not receiving calls.
Check that the unit connected to the 4+n connection block supports electronic calls and that
it is configured for this.
Check that the programming has been done correctly. Reprogram it if necessary.
CONFORMIDAD/COMPLIANCE/CONFORMITÉ
Este producto es conforme con las disposiciones de las Directivas Europeas
aplicables respecto Compatibilidad Electromagnética 89/336/CEE, así como con la
ampliación en la Directiva del Marcado CE 93/68/CEE.
This product meets the essentials requirements of applicable European Directives
regarding Electromagnetic Compatibility 89/336/ECC, and as amended for CE
Marking 93/68/ECC.
NOTA: El funcionamiento de este equipo está sujeto a las siguientes
condiciones:
(1) Este dispositivo no puede provocar interferencias dañinas, y (2)
debe aceptar cualquier interferencia recibida, incluyendo las que
pueden provocar un funcionamiento no deseado.
NOTE: Operation is subject to the following conditions:
(1) This device may not cause harmful interference, and (2) this device
must accept any received interference, including the ones that may
cause undesired operation.
golmar@golmar.es
www.golmar.es
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
35

Publicité

Table des Matières
loading

Table des Matières