Owner's Instruction and Operation Manual
Model Number:
WMPS7000
4840
Report #: F20-598
Certified to ASTM Std E1509-12 (2022) and
Certified to CAN/ULC S627:2023
Mobile Home / Transportable Building Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
World Marketing of America, Inc, 12256 William Penn Hwy, Mill Creek, PA 17060
R
Email: info@worldmkting.com PH: 1-800-776-9425
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
854131-1902N
www.P65warnings.ca.gov

Publicité

loading

Sommaire des Matières pour Comfort Glow WMPS7000

  • Page 1 Owner’s Instruction and Operation Manual Model Number: WMPS7000 4840 Report #: F20-598 Certified to ASTM Std E1509-12 (2022) and Certified to CAN/ULC S627:2023 Mobile Home / Transportable Building Approved 854131-1902N * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
  • Page 2 INTRODUCTION This manual describes the installation and operation of the Comfort Glow, WMPS7000, 4840 wood heater. This heater meets the 2020 U.S. Environmental protection agency’s crib wood emission limits for wood heaters sold after may 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 8,141 to 12,161 btu/hr output.
  • Page 3 INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-776-9425 COMMISSIONING CHECKLIST This checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference. Failure to install and commission according to the manufacturer’s instructions and complete this checklist will invalidate the warranty.
  • Page 4 ASSEMBLY INSTRUCTIONS Ensure the flame impingement baffle is installed properly. If the baffle is not installed properly, push the plate up in the void at an angle, rotate it to horizontal and place it on the metal stops. Flame Impingement Ba e INSTALLATION FOR CUSTOMER SERVICE CALL: 1-800-776-9425 WARNING:...
  • Page 5 INSTALLATION IMPROPER INSTALLATION CAUTION: The manufacturer will not be held responsible for damage CONTACT YOUR LOCAL BUILDING OFFICIALS TO caused by the malfunction of a stove due to improper OBTAIN A PERMIT AND INFORMATION ON ANY venting or installation. Consult a professional installer if ADDITIONAL INSTALLATION RESTRICTIONS OR you have any questions.
  • Page 6 INSTALLATION CLEARANCES MOBILE HOME/TRANSPORTABLE BUILDING REQUIREMENTS Your pellet stove has been tested and listed for installation in residential, mobile home/transportable building in WARNING! accordance with the clearances given below. For safety reasons, please adhere to the installation clearances and DO NOT INSTALL IN A SLEEPING ROOM restrictions.
  • Page 7 INSTALLATION WALL INSTALLATION 5. Carefully cut exhaust/intake through hole in exterior wall completely through to the outside (see “Vent Select a wall to the exterior of the building. This wall Clearances” section to ensure proper installation). should have the required clearance to combustibles inside and out as mentioned in this manual.
  • Page 8 INSTALLATION on the back of the unit. On the exhaust side of the unit there is a ring that is held on with four screws, it 6” needs to be removed so the transition piece can be (152 mm) mounted. Use the supplied Phillips head self-tapping screws to attach the transition piece.
  • Page 9 INSTALLATION Notes: A source of fresh air shall be provided when required. To ensure this make sure that the intake to the concentric • The horizontal run of venting must be level, or have a 1/4 vent system is clear of all obstructions during use. You inch rise for every 1 foot of run towards the termination.
  • Page 10 OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED HOW YOUR HEATER WORKS • Once the heater reaches a set temperature, the room fan will come on. Your pellet heater operates on a timer based auger fuel feed system, that is controlled by a digital circuit board. LIGHT (LED) INDICATORS The fuel is delivered from the auger into a burn pot, which •...
  • Page 11 OPERATION INSTRUCTIONS 10. Salt water driftwood or other previously salt water fumes irradiating from the appliance during this process. saturated materials; Follow the Start-Up procedure below to begin your burn. 11. Unseasoned wood; or START-UP PROCEDURE 12. Paper products, cardboard, plywood, or particleboard. The prohibition against burning these materials does WARNING: not prohibit the use of fire starters made from paper,...
  • Page 12 OPERATION INSTRUCTIONS SHUT DOWN PROCEDURE NOTE: The unit will also shut down in the event of an exhaust blower failure; if this is the case, the unit will not re-start and you must contact Customer Service. WARNING: The amount of visible smoke being produced can be NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT an effective method of determining how efficiently the FROM THE POWER SOURCE.
  • Page 13 MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED ASH REMOVAL WARNING: Remove the ashes periodically to avoid unnecessary ash • DISCONNECT THE POWER CORD BEFORE build up. Ash removal is as follows: PERFORMING ANY MAINTENANCE! NOTE: Let fire burn out and allow unit cool to room TURNING THE ON/OFF SWITCH TO ”OFF”...
  • Page 14 MAINTENANCE confined areas can be dangerous. Make sure your stove the event you need to replace the glass, Do not attempt gaskets and chimney joints are in good working order to operate the unit with broken glass. Replacement glass and sealing properly to ensure unintended exposure. It is may be purchased from your U.S.
  • Page 15 MAINTENANCE MAINTENANCE SCHEDULE Monthly or Daily Weekly Use the following as a guide under average use conditions. as needed Gaskets around door and door glass should be inspected Burn Pot Stirred Empty and repaired or replaced when necessary. Combustion • Failure to clean and maintain this unit as indicated can Brushed Chamber result in poor performance, safety hazards and void...
  • Page 16 TROUBLE SHOOTING ERRORS • Disconnect the power cord before performing any maintenance! NOTE: Switching the appliance to ”OFF” does not disconnect all power to the electrical components of the heater. • Never try to repair or replace any part of the heater unless instructions for doing so are given in this manual or supplied from the factory.
  • Page 17 TROUBLE SHOOTING ERRORS With the stove on, check to see if the combustion blower is running. If it is not, Combustion blower failure. you will need to check for power going to the combustion blower. It should be a full current. If there is power, the blower is bad. Control board not sending power to If there is no current going to the combustion blower, check all wire connections combustion blower.
  • Page 18 WIRING DIAGRAM ENSURE THE WIRES ARE CONNECTED TO THE BOTTOM TWO PRONGS OF THE HOPPER SWITCH AS SHOWN. CORRECT WRONG...
  • Page 19 REPAIR PARTS...
  • Page 20 REPAIR PARTS Part # Description Part # Description Distribution Fan Enclosure 26231 RTD Mounting Bracket 893318 Panel 80694 Platinum RTD 893319 Distribution Fan Enclosure 88179 LT Chamber Insulation 3" Double Centrifugal Blower 88178 Wrapped Chamber Insulation 80542 - 125CFM 26360 Exhaust/Intake Beauty ring 26210 Room Fans Extenders...
  • Page 21 SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
  • Page 22 LIMITED WARRANTY Limited Warranty (Wood and Pellet Stoves) Warranty Period Branded Solid Fuel Burning Products Component Parts Labor Pellet Wood Component Parts Covered by this Warranty Cast Iron Components, Steel liners, Retainers, Gaskets, Firebrick and All 2 Years from Electrical Components. All Parts including handles, external enameled Date of Purchase components and other material except as covered by Warranty conditions, Warranty Exclusions, and Warranty Limitations listed.
  • Page 23 LIMITED WARRANTY • WMAI’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Information is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consideration must be given to appliance location and configuration, environmental conditions, insulation and air tightness of the structure.
  • Page 24 NOTES...
  • Page 25 NOTES...