INSTALLATION
CAUTION:
CONTACT YOUR LOCAL BUILDING OFFICIALS TO
OBTAIN A PERMIT AND INFORMATION ON ANY
ADDITIONAL INSTALLATION RESTRICTIONS OR
INSPECTION REQUIREMENTS IN YOUR AREA.
Your heater should be installed by a qualified NFI (US) or
WETT (Canada) technician. To find the nearest qualified
installer, go to:
https://nficertified.org,
https://www.wettinc.ca/
INSTALLATION OPTIONS
Read this entire manual before you install and use your
pellet stove. Failure to follow instructions may result in
property damage, bodily injury, or even death! Before
installing your heater, you must perform an initial burn in
an OUTSIDE environment. Follow the Start-Up Procedure
in the "Operation" section of this manual. See specific
installation details for clearances and other installation
requirements. Your pellet stove may be installed to code
in either a conventional or mobile home/transportable
building (see Standard Mobile Home/Transportable
building Requirements). It is recommended that only a
authorized technician install your heater, preferably a
National Fireplace Institute (NFI) certified specialist.
This heater must be installed on an exterior wall to
allow exhaust venting to meet the minimum required
clearances. Once the desired location is selected, and
before cutting a hole, check the outside of the structure
for anything obstructing clearances to the exhaust vent.
Also clear away leaves, shrubs/bushes, or trees that may
be around the exhaust outlet.
CAUTION:
BEFORE INSTALLING YOUR HEATER, YOU MUST
PERFORM AN INITIAL BURN IN AN OUTSIDE
ENVIRONMENT.
FOLLOW
PROCEDURE IN THE OPERATION SECTION OF
THIS MANUAL.
THE
START-UP
5
IMPROPER INSTALLATION
The manufacturer will not be held responsible for damage
caused by the malfunction of a stove due to improper
venting or installation. Consult a professional installer if
you have any questions.
EXHAUST LOCATIONS
FLOOR PROTECTION
This heater must have a non-combustible floor protector
(ember protection) installed beneath it if the floor is of
combustible material. If a floor pad is used, it should be
UL listed or equal. The floor protector should be large
enough to extend under the stove and beyond each side as
indicated. A Floor Protector of 1/4" thick is recommended
for this installation
A
B
A
Sides
USA 2" (51 mm) CAN 8" (200 mm)
B
Front
USA 6" (152 mm) CAN 18" (450 mm)
16.02"
(407 mm)
A
Floor Protector