10. Possible causes of failure
Problem
The compressor
does not start
The compressor
starts but there is no
pressure
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
Anl_TE_AC_270_50_Silent_SPK13.indb 18
Anl_TE_AC_270_50_Silent_SPK13.indb 18
GB
Cause
1. No supply voltage.
2. Insuffi cient supply voltage.
3. Outside temperature is too low
4. Motor is overheated
1. Leak in the non-return valve
(14)
2. The seals are damaged.
3. The drainage cock for conden-
sation water has a leak.
1. Loose hose connections.
2. Leak in a quick-lock coupling.
3. Insuffi cient pressure set on the
pressure regulator.
- 18 -
Solution
1. Check the cable, power plug, fuse and
socket-outlet.
2. Make sure that the extension cable is
not too long. Use an extension cable
with large enough wires cross-sections.
3. Do not use at an outside temperature
below +5° C.
4. Allow the motor to cool down. If neces-
sary, remedy the cause of the overhe-
ating.
1. Replace non-return valve (14)
2. Check the seals and have any dama-
ged seals replaced by a service center.
3. Check the drainage cock and replace if
necessary.
1. Check the compressed air hose and
tools and replace if necessary.
2. Check the quick-lock coupling and re-
place if necessary.
3. Increase the set pressure with the pres-
sure regulator (3).
11.04.2024 11:45:59
11.04.2024 11:45:59