6.
Safety:
Use extreme caution when the laser beam is turned on.
Do not point the laser at eyes.
Do not allow the beam to strike the eye from a reflective surface.
Do not point the beam toward anyone or any animals.
Do not use the laser near explosive gases.
7.
Maintenance:
Do not use volatile liquids to clean the unit, swipe it with dry soft cloth.
Do not immerse it in water.
Do not store it in high temperature or humidity.
8.
Notes:
Work Principle
The infrared thermometer is designed for measuring surface temperature of an object.
The optical sensor can emit, reflect and transmit energy, which is collected and focused on a detector, then translate it into the
temperature reading by electronics and displayed on the LCD screen.
The laser is used for aiming the target object only.
Field of View
The object under test should be larger than the spot size calculated by the field of view diagram.
The smaller the target object is, the closer the meter should be to it for accurate measuring.
When accuracy is critical, make sure the target is at least twice as large as the spot size.
Distance and spot size : As distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger.
Locating a hot spot : to find a hot spot, first aim the thermometer to the outside of target area, then scan across in an up and down
motion until the hot spot is located.
Other important notes :
If the thermometer is used at room temperature and then moved to an area with a significant temperature difference, allow the
device to adjust for 30 minutes before use.
This device is not recommended for measuring shiny or polished metal surfaces like stainless steel, aluminum, etc.
Do not take measurements through a transparent surface, such as glass.
If the surface of the object being measured is covered with frost, oil, dirt, etc., clean it before taking the measurement.
9.
Specifications:
Range
Accuracy
Emissivity
Optical Resolution
Response Time
Resolution
Spectral Response
Polarity Display
Diode Laser
Auto Power Off
Operating Temp.
Storage Temp.
Relative Humidity
Power Supply
Dimensions (L*W*H)
Weight
18/10/2024 / V2
‐50℃~580℃/‐58℉~1076℉
‐50℃~0℃/‐58℉~32℉:±3℃/5,4℉
0℃~580℃/32℉~1076℉:±2% or ±2℃/±3,6℉ whichever is
greater
Adjustable 0.1~1.0
D:S=13:1
≤500ms
0.1℃ (0.1℉)
8~14um
Auto display, "‐" indicates negative, while positive with no sign.
Output<1mW, Wavelength 630~670nm, Class Ⅱ
Meter shuts off automatically after 20 seconds of inactivity
0℃ to 50℃ / 32℉ to 122℉
‐20℃ to 60℃ / ‐4℉ to 140℉
Operating:10~95%RH, Storage:<80%RH
9V battery
155*100*42mm
176g (with battery)
STIL – 254 rue Foch – Vaux le Pénil – France – www.stil.fr