Instructions for use: 5512 infrared thermometer 
This infrared thermometer has the particularity of easily and quickly measuring the surface temperature while programming an alarm that can 
have 3 different limits in relation to the reference temperature (+/‐0.5°C, +/‐3°C or +/‐5°C).
 
1.
Key features 
Built‐in laser pointer  
Backlit LCD screen 
3 temperature tolerances 
Temperature alarm 
Low battery indicator 
Maximum and minimum temperature  
recordings  
Adjustable emissivity 0,1 to 1,0 
Auto‐off after 20 seconds 
°C/°F Selection 
 
3.
Using the device 
1.
To measure the temperature, point the thermometer at the area to be measured and press the trigger. The « SCAN » icon will appear. 
2.
Alarm temperature (reference): by default the temperature is set to 0°C.  
To modify this : first, press and hold the trigger, then press the « SET » button while holding the trigger. The « REF » 
indicator will flash. Release the buttons. Press and hold one of the D « left » or E « right » buttons (see the drawing 
on the right) to change the alarm temperature.  Press « SET » to confirm. 
The device will remember the reference temperature until the battery is changed. To modify the reference again, repeat the procedure.  
3.
To set the alarm threshold: turn on the device and press the « left » or « right » button to select the desired tolerance: +/‐0.5°C, +/‐
3°C or +/‐5°C relative to the reference temperature. To disable the reference temperature function: select the « OFF » icon. 
4.
Alarm: The measured temperature will automatically be compared to the selected reference temperature with the chosen limit. 
If the measured temperature remains within the selected range: the screen will be green. 
If the temperature exceeds the limit: the screen will turn red and beep quickly (if the trigger is held).  
If the temperature is below the limit: the screen will turn blue and beep slowly (if the trigger is held). 
If the alarm is set to "OFF" : the screen will appear yellow 
 
4.
Settings: 
To choose the measurement unit (°C or °F): press the "SET" button. 
To adjust the emissivity: press and hold the "SET" button for 3 seconds, then adjust the emissivity using the « left » and « right » 
buttons. Press "SET" again for 3 seconds to save the selected emissivity.  Note: The default emissivity is set to 0,95. 
 
5.
Battery replacement: 
When the low battery icon appears 
To do this, open the battery compartment, replace the 9V battery and close the battery compartment cover. 
 
 
 
 
 
 
 
 
 
 
18/10/2024 / V2 
2.
Device Description 
A.
Laser pointer beam    
B.
Infrared sensor 
C.
LCD screen 
D.
« Left » button 
E.
« Right » button 
F.
« SET » button 
G.
Measurement trigger 
H.
Battery compartment 
 
, replace the device's battery.  
STIL – 254 rue Foch – Vaux le Pénil – France – www.stil.fr 
 
Screen 
1.
Low battery indicator 
2.
« SCAN » icon 
3.
Measurement result 
4.
« REF » function activated or not 
5.
Defined values 
6.
Temperature units 
7.
Temperature reference 
8.
« REF » Icon 
 
or
 

Publicité

loading

Produits Connexes pour STIL 5512