A.
HEATER MAINTENANCE CHECKLIST
WARNING. Heater should only be serviced by qualified personnel with heating equipment experience. Lock the
switch in the "OFF" (open) position and/or tag the switch to prevent unexpected power application.
WARNING
Heater Model
Serial Number
Comments
A.1     Period
1.
Clean
(before and as required during heating season)
Finned Elements
Fan
Fan Guard
Motor
Louvers
Wash with water pressure less than 70 psi.
A.2     Annual
1.
Electrical
(before heating season)
Check all terminal connections and conductors.
Tighten loose connections. Conductors with
damaged insulation must be replaced.
2.
Mechanical
Electrical junction box. Inside of enclosure must
be clean, dry, and free of foreign materials. Cover
must be completely on and tight.
Check motor shaft bearing play. Replace motor if
play is excessive or if motor does not run quietly
and smoothly. Motor bearings are permanently
lubricated.
Check fan. Replace immediately if cracked or
damaged.
Check louvers. Louver screws should be tight.
Louvers are not to be closed more than 75˚ from
horizontal.
Date of Maintenance
Maintenance Done By
2.
Check
Motor for smooth, quiet operation
Electrical junction box cover for tightness
Check the tightness of all hardware. All nuts and
bolts, including mounting hardware, must be
tight.
TURN HEATER MOTOR ON FOR A MINIMUM OF
15 MINUTES. Check for air exiting heater through
louvers and smooth running of fan motor.