I.
1
2
4
5
3
6
II.
1.
2.
4.
4.
5. 5.
I.
Description
1
Handle
2
Air outlet of heating unit
3
Stand
4
Air intake of fan
5
Main switch
6
Supply cord
7
7
Thermostat switch
II.
Operation
3. 3.
Caution: Remove any packaging before use. Store packaging out of reach of children and use it to
protect the heater during standstill. Check the heater, the power cord, and the power plug for damages.
Do not use the heater if there are any visible signs of damage.
1.
Position the heater on a firm and absolutely level underground observing the spacing shown in fig. 1 on
the left flap-out-page.
2.
Plug the appliance to a suitable 220-240 V~50 Hz socket with protective earth.
3.
Turn the thermostat switch to MAX.
4.
Switch on the heater by turning the main switch to one of the power levels (
heating power;
6.
the heat unit. If the main switch is set to
temperature is below the one scheduled for the set power level.
5.
Turn the main switch to 0 to switch off the heater.
6.
Always unplug the appliance when not in use.
III.
III.
Maintenance and care
Caution: Before performing any maintenance and care always unplug the heater and let it cool down.
Cleaning
Wipe the heater with a soft, damp cloth only. Never use scouring powders or chemical cleaning agents.
Never allow the electrical components to become damp.
54 54
Technical data
Nominal voltage
220-240 V~ 50 Hz
Rated power
3000 W
Current
12.5-13.6 A
Protection class
II
Degree of protection
IP 20
Overheat protection
70 °C
= fan only;
= medium
= high heating power). The fan works in all power levels and switches on and off with
or
then the heat unit switches on as soon as the ambient
IV.
Trouble shooting
Problem
Cause
The fan does not work although
The power supply is off.
the main switch is switched on.
The heater does not heat.
Main switch set to 0 or
The ambient temperature is
above the temperature scheduled
for the set power level at the main
switch.
The overheat protection shut
down the heater.
Strange noise
The heater does not stand
upright.
Solution
Check the fuse. Do not connect the
heater and other appliances to the
same circuit.
Set the main switch to
or
.
Wait until the ambient temperature
falls below the set value.
Increase the power level with the
main switch.
Make sure that neither the air
intake nor the air outlet is blocked.
Unplug the heater and let it cool
down for at least 10 min.
Position the heater upright on an
even surface.
55 55