LED Indications during FAULTS
SI.No
LED Indication
All LEDs (Green, Amber & Red)
together blink 3 times
1
After that Amber blinks 2 times
All LEDs (Green, Amber & Red)
together blink 3 times
2
After that Amber and Red
blinks alternately
Red LED Blinks 3 times
3
Amber LED glows 2secs and
4
then Red Blinks
Green LED Blinks
5
PLEASE REFER TO THE BACK OF THE MANUAL FOR PICTORIAL INSTRUCTIONS
7
Error
Error Description
Motor Power wires (RED & BLACK) at
-J1 & -J2 are Loose / Disconnected
from PCB
Low Current
Motor speed signal wires (Multicore
cable) at –J8 Connector are Loose /
Disconnected from PCB
High Current due to carpet / Foreign
High Current
parts struck in between the brush &
drum
Main Rocker Switch S1 is kept ON
Charger ON
while Charger is Connected to
Sense
battery
In correct
Operator lowers the handle & then
START
Switch ON the Main battery Switch
sequence
(S1)
This indicates that the Handle is
Dead man
down fully, such that it is almost
Switch (-S4)
parallel to the floor. The machine
is activated
goes OFF for safety purpose
Remedy
Check the wires, Rectify the
cause & Restart.
Rectify the cause & Restart.
During Charging, Main Rocker
Switch S1 should be in Turned
OFF Condition.
Main battery Switch (S1) is to
be turned ON first and then
only handle to be lowered
Lifting the handle up slightly,
makes machine operate
normally.
(11-24)