3.
Proceed at a moderate work-rate, the use of too much force will impair efficiency.
CAUTION After long time of use, the cylinder case becomes hot. Therefore,
be careful not to burn your hands.
WARNING Don't apply big pressure to the machine. The hammer
mechanism is activated by applying a slight pressure on the tool when the
chisel bit is in contact with the work-piece.
9 LUBRICATION - OIL LEVEL
Check the grease level before using the machine.
The grease should be changed after around 40-50 hours of use.
Recommended grease: 25ml SAE 15W/40 or an alternative of the same quality.
9.1
Oil change
Before feeding grease, use the provided wrench to remove the grease gauge (4). Be
careful not to lose the rubber packing attached below the grease gauge.
Check the grease level once daily, confirming that grease is filled.
After feeding grease, securely clamp the grease gauge
Important: The waste grease must be disposed of in the appropriate
collection point for waste grease.
10 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
10.1
Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
11 TECHNICAL DATA
Rated Voltage
Rated Frequency
Rated Power
Rotation speed
Protection class
Drill capacity concrete
Drill capacity steel
Drill capacity wood
Impact rate
Cable length
Copyright © 2024 VARO NV
POWX1195
230 V
50 Hz
1500 W
-1
860 min
II
32 mm
13 mm
42 mm
-1
4250 min