SIDEWALL AND BACKWALL INSTALLATION
Unit to Sidewall ----------------------------------------- 32"
Unit to Backwall ---------------------------------------- 10"
Connector to Sidewall --------------------------- 39 1/2"
Center of Connector to Sidewall ------------------- 44"
Connector to Backwall -------------------------------- 12"
Center of connector to Backwall ------------------- 16"
16"
8"
32"
39 1/2"
44"
FIGURE 1
Hearth dimensions shown are minimum requirements. It may be desired to exceede these mini-
mum dimensions for a more decorative installation. The hearth material must be 3/8" or thicker
noncombustible material. It is not required for the hearth material to extend under the base of the
fireplace.
CLEARANCES
Minimum Hearth Size --------------------------------54" x 32 1/2"
Hearth is not required to extend under the Zircon's base.
54"
8"
12"
16"
10"
CORNER INSTALLATION
Unit to Adjacent Wall ------------------------------------ 10"
Connector to Adjacent Wall ---------------------- 15 1/2"
Center of Connector to Adjacent Wall -------------- 20"
32 1/2"
10"
20"
15 1/2"
Page - 3
15 1/2"
20"
10"
FIGURE 2
Zircon 38 3/13/15