Assembly And Installation Instructions
LEAVE THESE INSTRUCTIONS WITH THE OWNER.
If this fireplace is not properly installed, a house fire may result. To
reduce the risk of fire, follow the installation instructions.
Contact local building or fire officials about restrictions and installation
inspection requirements in your area.
This stove must be connected to (1) a chimney complying with the
requirements for Type HT chimneys in the Standard for Chimneys,
Factory-Built, Residential Type and Building Heating Appliance, UL 103,
or (2) a codeapproved masonry chimney with a flue liner.
Please read this entire manual before you install and use your new
fireplace.
Failure to follow instructions may result in property damage, bodily
injury, or even death.
DO NOT INSTALL THIS UNIT IN A MOBILE HOME.
Malm Fireplace, Inc.
368 Yolanda Avenue - Santa Rosa, Ca. 95404
(707) 523-7755 Fax: (707) 571-8036
Tested to UL737 & ULC-S627-00
SAFETY NOTICE
ZIRCON 38
Listed By LabTest
Tested to U/L Standards
Tested to UL737 & ULC-S627-00
Certified for use in USA & Canada
Certifié pour une utilisation aux
Etats-Unis et Canada
Zircon 38 3/13/15

Publicité

loading

Sommaire des Matières pour Malm Fireplace ZIRCON 38

  • Page 1 (2) a codeapproved masonry chimney with a flue liner. Please read this entire manual before you install and use your new fireplace. Failure to follow instructions may result in property damage, bodily injury, or even death. DO NOT INSTALL THIS UNIT IN A MOBILE HOME. Zircon 38 3/13/15...
  • Page 2 8 inches from the original combustible wall. Be certain to check with your local building officials and or fire inspector for accepted methods in your area. Refer to NFPA 211. Page - 2 Zircon 38 3/13/15...
  • Page 3 Hearth dimensions shown are minimum requirements. It may be desired to exceede these mini- mum dimensions for a more decorative installation. The hearth material must be 3/8” or thicker noncombustible material. It is not required for the hearth material to extend under the base of the fireplace. Page - 3 Zircon 38 3/13/15...
  • Page 4 There are different accepted methods of connecting the fireplace to a masonry chimney through a combustible wall. This type of installation requires the use of a thimble to protect the surrounding combustible materials. Check with your local building officials or consult NFPA211. See Figure 4, Page 6. Page - 4 Zircon 38 3/13/15...
  • Page 5 Included with the Zircon 34 is the following: 1 - 9” x 24” damper pipe 2 - 9” x 24” pipe section 1 - 9” to10” Adapter 10 - 6lb bags of Malmcrete refractory Page - 5 Zircon 38 3/13/15...
  • Page 6 2” Clearance From Studs To Chimney Walls Header Header 12” Of Brick From Liner To Combustibles 5/8” Fireclay Liner Minimum or Equivalent 12” 12” Of Brick From Liner Minimum To Combustibles Sill/Support Figure 4 Page - 6 Zircon 38 3/13/15...
  • Page 7 Fire Department inspect the chimney for you. Never use a flammable liquid to kindle or rekindle a fire. 6. Never use coal in a fireplace. Coal should be used only in stoves especially designed to burn coal. If the toxic gases produced enter the room they can be fatal. Page - 7 Zircon 38 3/13/15...
  • Page 8 NEVER STORE OR ALLOW PAPERS, KINDLING, FIREWOOD OR ANY OTHER COMBUSTIBLES WITHIN 48 INCHES OF UNIT. Malm Fireplaces, Inc. 368 Yolanda Avenue Santa Rosa, Ca 95404 (707) 523-7755 - (800) 535-8955 Fax: (707) 571-8036 www.malmfireplaces.com info@malmfireplaces.com Page - 8 Zircon 38 3/13/15...
  • Page 9 Se il vous plaît lire l’intégralité de ce manuel avant d’ installer et d’utiliser votre nouveau foyer. Le non-respect des instructions peut entraîner des dommages matériels, des blessures, voire la mort. NE PAS INSTALLER CET APPAREIL DANS UNE MAISON MOBILE. Page - 9 Zircon 38 3/13/15...
  • Page 10 être réduite à 8 pouces du mur combustible d’origine. Soyez certain de vérifier avec votre bâtiment local fonctionnaires et inspecteur des incendies ou des méthodes acceptées dans votre région. Reportez-vous à la norme NFPA 211. Page - 10 Zircon 38 3/13/15...
  • Page 11 Le matériau de l’âtre doit être 3/8 “ou matériaux incombustibles plus épais. Il ne est pas nécessaire pour le matériau de foyer pour se étendre sous le fond de la cheminée. Page - 11 Zircon 38 3/13/15...
  • Page 12 à une cheminée de maçonnerie à travers un mur combustible. Ce type d’installation nécessite l’utilisation d’un doigt de gant pour protéger les matériaux combustibles environnants. Vérifiez auprès de votre administration locale de construction ou consultez NFPA211. Voir Figure 4, Page 14. Page - 12 Zircon 38 3/13/15...
  • Page 13 1 - 9 x 24 tuyau d’amortisseur 1 - 9 x 24 section de tuyau 1 - 9 x 24 tuyau de la section de glissement 10 - 6 de sacs de Malmcrete réfractaire. Page - 13 Zircon 38 3/13/15...
  • Page 14 51mm Dégagement des montants Pour Cheminée Murs Header 305mm De Brick D Liner pour combus- tibles 5/8” 15.8mm fireclay Liner Minimum ou équivalent 305mm 305mm De Brick De Minimum Liner pour combus- tibles Soutien/Sill Figure 4 Page - 14 Zircon 38 3/13/15...
  • Page 15 6. Ne utilisez jamais de charbon dans une cheminée. Coal doit être utilisé que dans les poêles spécialement conçus pour brûler du charbon. Si le toxiques gaz produits entrent dans la salle, ils peuvent être mortels. Page - 15 Zircon 38 3/13/15...
  • Page 16 Ne rangez jamais OU LAISSER papiers, POELE, bois de chauffage ou D’AUTRES COMBUSTIBLES dans les 48 POUCES de l’appareil. Malm Fireplaces, Inc. 368 Yolanda Avenue Santa Rosa, Ca 95404 (707) 523-7755 - (800) 535-8955 Fax: (707) 571-8036 www.malmfireplaces.com info@malmfireplaces.com Zircon 38 3/13/15...

Ce manuel est également adapté pour:

Zircon 34