POWERING & CONNECTING
Grounding the Switch
1. Remove the ground screw from the back of switch, and
connect one end of the ground cable to the wiring terminal
of switch.
2. Put the ground screw back into the screw hole, and tighten
it with a screwdriver.
3. Connect the other end of the ground cable to other device
that has been grounded or directly to the terminal of the
ground bar in the equipment room.
Powering on the Switch
Connect the power cable and the switch first,
then connect the power cable to the power supply
system of the equipment room.
Connecting Power Cord Anti-Trip
In order to protect the power supply from accidental
disconnection, it's recommended to use a power cord
anti-trip for installation.
1. Force the head of the fixing strap tightly into
the hole next to the power socket until it's
buckled on the shell without falling off.
2. After plugging the power cord into the power
outlet, slide the protector over the remaining
strap until it slides over the end of the power
cord.
3. Wrap the strap of the protective cord around
the power cord and lock it tightly. Fasten
the straps until the power cord is securely
fastened.
PORT CONNECTING
Connect to SFP+ Port
The installation process of the fiber module is as follows:
1. Grasp the fiber module from the side and insert it
smoothly along the switch SFP+ port slot until the
module is in close contact with the switch.
2. When connecting, pay attention to confirm the Rx and
Tx ports of SFP+ fiber module. Insert one end of the
fiber into the Rx and Tx ports correspondingly, and
connect the other end to another device.
3. After powered on, check the status of the port indicator. If on, it means that the link is connected normally; if off, it
means the link is disconnected, please check the cable and the peer device whether is enabled.
Notes:
• Please select the optical fiber cable according to the module type. The multi-mode module corresponds to the
multi-mode optical fiber, and the single-mode module corresponds to the single-mode optical fiber.
• Please select the same wavelength optical fiber cable for connection.
• Please select an appropriate optical module according to the actual networking situation to meet different
transmission distance requirements.
• The laser of the first-class laser products is harmful to eyes. Do not look directly at the optical fiber connector.
Ground Terminal
Ground Cable
Ground Bar
SFP+ port
~ 3 ~
Connect to Console Port
1. Connect the console cable (prepared by yourself) to the DB9 male connector or USB port to the PC.
2. Connect the other end of the RJ45 end of the console cable to the console port of switch.
Connect to Console Port (DB9)
Notes:
• To connect, the steps order (1 -> 2) must be respected.
• To disconnect, the steps order is reversed (2 -> 1).
INSTALLATION
Install on the Desktop
1. Place the bottom of switch on a sufficiently large and
stable table.
2. Peel off the rubber protective paper of the four footpads
one by one, and stick them in the corresponding circular
grooves at the four corners of the bottom of the case.
3. Flip the switch over and place it smoothly on the table.
Install on a 19" Standard Rack
1. Check the grounding and stability
of the rack.
2. Install the two L-shaped rack-
mounting in the accessories on
both sides of switch, and fix them
with the screws provided (KM
3*6).
3. Place the switch in a proper
Fiber
position in the rack and support it
module
by the bracket.
4. Fix the L-shaped rack-mounting
to the guide grooves at both ends
of the rack with screws (prepared
by yourself) to ensure that the
switch is stable and horizontally
installed on the rack.
Note
To avoid high temperatures and keep the
device cool, sufficient space should be
left around the switch for heat dissipation.
The air inlet of the switch cannot face or
be close to the air outlet of other devices.
Connect to Console Port (USB)
Circular groove
Air inlet
~ 4 ~
Rubber footpads
Air outlet
Fans