4.3.1. SETTING OF CURRENT DAY AND TIME
1.
Switch the radiator to standby state.
2.
Press and hold "Programming" key for more than 3 seconds: the display shows "Prog", meaning
programming or "tEd", meaning time and date.
3.
With "+" key it is possible to switch from "Prog" to "tEd" selection.
4.
When "tEd" is displayed, press "Function" key to confirm your selection.
5.
Set the current year using "+" and "-" keys press "Function" key to confirm your selection.
6.
Set the current month using "+" and "-" keys press "Function" key to confirm your selection.
7.
Set the current day using "+" and "-" keys press "Function" key to confirm your selection.
8.
Select the day of the week among 1 (Monday), 2 (Tuesday),... and 7 (Sunday) using "+" and "-" keys.
9.
Press "Function" key to confirm your selection.
10.
Now the current time is displayed and the figures indicating time are flashing; time can be set
using "+" and "-" keys.
11.
Press "Function" key to confirm your selection.
12.
The figures indicating minutes are flashing; minutes can be set using "+" and "-" keys.
13.
Press "Function" key to confirm your selection, the radiator goes back to standby mode.
14.
If no key is pressed within 30 seconds, the system goes back to standby mode and modifications
carried out are kept.
4.3.2. PROGRAMMING
1.
Switch the radiator to standby state.
2.
Press and hold "Programming" key for more than 3 seconds: the display shows "Prog", meaning
programming or "tEd", meaning time and date.
3.
With "+" key it is possible to switch from "Prog" to "tEd" selection.
4.
When "Prog" is displayed, press "Function" key to confirm your selection.
5.
Using "+" and "-" keys and for each hour of the day, select the comfort temperature level (full
bar in the lower part of the display) or the night temperature level (short bar in the lower part of
the display) of day 1 (Monday).
6.
Press "Function" key to confirm the programming selection of the first day (day 1, Monday)
7.
Repeat the same procedure for programming the remaining days from 2 to 7.
Now the weekly programming is set and remains stored as P3 parameter, and can be changed by
repeating the operation described above.
Note: "Comfort" and "night" temperatures are those set in the two relevant modes. It is not possible to select
a night temperature higher than the comfort temperature, since the electronic system does not allow that.
During operation, it is possible to change the temperature of the current time slot by pressing "+" and
"-" keys
5. RADIATOR CLEANING
For your safety, before any cleaning operation, disconnect power supply.
Cleaning operations must be carried out with radiator off and cold.
Do not use abrasive or corrosive products to clean the heating body. Use, for instance, soapy water
and then dry the body using a soft cloth.
To clean plastic components, controls and humidifier, use only a dry cloth and avoid contact with
chemicals or alcohol.
6. FAILURES
In case of failure do not use the appliance, disconnect it from power supply and for the repair address
only to a technician approved and authorised to operate on this product.
This appliance is filled with a precise quantity of mineral oil. Reparations that require to open the fluid
tank must be carried out by the manufacturer, its agents or the customer service.
The manufacturer shall not be held responsible for damage to people, animals, or property due to
tampering with or improper intervention to the radiator.