GB
TROUBLE SHOOTING
If the dehumidifier does not operate:
• Make sure the unit is plugged in.
• Ensure the humidistat control is turned on.
If the unit is noisy:
• Make sure the dehumidifier is standing solidly and level.
If the unit is leaking:
• Check the drainage tube for correct fitting.
• Check for twists and bends in the drainage tube.
• Check the drainage tube for a sufficient slope.
• Check and make sure that the outlet of the drainage pipe is not under the water-
level in the drain.
TECHNICAL DATA
Model
Mains
Power consumption
Current (
operation
Current (
at start
Water extraction
30 °C, 70 % RH
30 °C, 80 % RH
32 °C, 90 % RH
IP code
Refrigerating agent R290*
Airflow (
at high fan speed
Operating temperature
Dimensions
w x h x d
Weight (
)
net
The room must have a minimum floor area of 15m
R290
brennbares
Naturgas
Disposal
Waste electrical and electronic products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.
)
)
at
)
D850E
220–240 V / 50 Hz
W
970
A
4.3
A
20
L/24h
52
60
63
IP24
g
300
3
m
/h
500
°C
mm
kg
37
2
Made in P.R.C. Specifications may change without prior notice.
8
D950E
1250
5.6
22
61
76
81
IP24
300
680
7 – 35
660 x 750 x 345
39