Absolute ENCODER S1 (optional)
–
This has the same features as index S1.
–
Can be used as main index on gas meters.
–
Available as a top-mounted unit (transmitter unit) on
meterswithmechanicalindexdrive(MI-2).
–
The encoder is suitable for connection to a series-
connected additional device (volume corrector, data
logger or bus system) in potentially explosive atmos-
pheres(seetable:TechnicalData).Adeviceconnected
totheterminalboxmustfeatureatleastthefollowing
approvalasanassociatedapparatusforthis:
[ Ex ia IIC ]forversionwithNamurinterface,
[ Ex ib IIC ]forversionwithSCR/SCR+interface,
[ Ex nA [ic] IIC ]forZone2installation(Namur/SCR/SCR+interface).
TheversionwithM-BUSinterfaceisnotATEXapproved.
Connection of the Absolute ENCODER S1 unit to the mechanical index drive of the meter
–
Connect the connector of the top-mounted unit to the mechanical index drive of the driving
unit(e.g.MI-2,ensurethesteeldiscisremovedfromtheconnector).
– Usealockingscrewtosecuretheencodertop-mountedunitagainstpullingout.
– Thelockingscrewmustbelead-sealedforapplicationsrequiringmandatorycalibration.
Connection of the encoder
–
Use
only
a
screened
(DIN EN 60079-14) to connect the
encoder and ensure that the pin
assignment is correct (see sticker
next to the cover of the terminal
box).
– When connecting the Namur interface, ensure that the 2-wire connection has the correct
polarity. The M-Bus and SCR/SCR+ interfaces are independent of the polarity.
– Itispossibletoapplyscreeningandtorunacabletothemeterhousingorthepipe.Make
suretocheckinadvancethatthegroundingsystemusedallowsgroundingonbothsides
(ground loops and potential difference in grounding).