4. CONTROLS
Key
Function
Turns the motor on/off at the first speed.
A
Decreases the operating speed.
B
C
Increases the operating speed.
D
Activates/Deactivates the motor at Intensive speed.
This speed is timed for 6 minutes. When the time is up, the system automat-
ically returns to the previous speed.
Long press when all loads are off (Motor+Light):
Activates/Deactivates the Activated Carbon Filters alarm.
E
24h Function
Activates/Deactivates the motor in the 24h mode, a speed that allows suction
of 10 minutes every hour, for a 24-hour cycle.
With the filters alarm in progress, pressing the button for approximately 3
seconds resets the alarm.
These signals are only visible with the motor off.
F
Delay Function
Activates the automatic shutdown delayed by 30'.
Ideal for eliminating any residual odours.
It can be activated from any position and is deactivated by pressing the but-
ton or by switching off the motor.
G
Switches the lighting system on and off to maximum brightness.
H
Turns the lighting system on and off in Courtesy Light mode.
When turned on, the card recognises
the mains frequency.
Recognition is indicated on the display:
• 50Hz: the number "50" will appear on
the display for one second
• 60Hz: the number "60" will appear on
the display for one second
Auto-Vent
This is an advanced automatic function
that connects the hob to a special hood.
Both the hob and the hood have an in-
fra-red signal communicator. The fan
12
speed is automatically defined based on
the mode settings and on the temperat-
ure of the hottest pan on the hob. It is
also possible to operate the fan from the
hob manually.
Automatic activation of the function
To automatically activate the function,
set the automatic mode from H1 to H6.
The hob is factory set to H5. The hob re-
acts every time the hob is used. The hob
automatically detects the temperature of
the pans and adjusts the fan speed.
Automatic modes
LED
Displays the speed set.
Displays the speed set.
Displays the speed set.
Alternately displays HI and the re-
maining time once per second.
FC+Dot (2 Flashes)–Alarm Active.
FC+Dot (1 Flash)–Alarm Deactiv-
ated.
Displays 24 and the lower right dot
flashes once per second while the
motor is in operation.
It is disabled by pressing the key.
FF flashes three times.
At the end of the procedure, the
previously displayed signal goes
out:
FG indicates the need to wash the
metal grease
filters. The alarm goes into opera-
tion after 100 hours of
actual work of the hood.
FC signals the need to replace the
activated carbon filters
and the metal grease filters must
also be washed. The alarm goes
into operation after 200 hours of
actual hood work.
Displays the operating speed and
the lower right dot flashes once
per second.
-
-