Télécharger Imprimer la page

Nilfisk-cfm T40W IC Manuel D'instructions page 23

Publicité

T40W IC / VHT446 IC
Translation of the original instructions
Controls, indicators and connections
1.
Dust container release lever
2.
Caster lever
3.
Start/stop switch
Inspections prior to starting
1.
Inlet
Prior to starting, check that:
The filters are installed;
All latches are tightly locked;
The vacuum hose and tools have been correctly fitted
into the inlet (1);
The bag or safety container is installed, if applicable.
Do not use the vacuum cleaner if the filter is faulty.
Starting
1.
Caster brakes
2.
Start switch
Lock the caster brakes (1) before starting the vacuum cleaner.
Starting/stopping the vacuum cleaner
Turn the switch (2) to "I" position to start the vacuum
cleaner.
Turn the switch to "0" position to turn the vacuum cleaner
off.
Checking the rotation direction of the vacuum unit
motor
Check the vacuum cleaner operation by putting a hand on the
inlet.
If the vacuum cleaner expels the air from the vacuum hose,
the rotation direction is not correct; remove the plug from the
GB
socket and turn the selector inside the plug to perform the
correct phase connection or invert two of the three phase
wires inside the power plug.
US
When the job is done, before turning off the vacuum
cleaner it is recommended to keep the vacuuming unit
running for at least three minutes without collecting dust, in
order to obtain a better cleaning of the cartridges.
C405
Figure 4
Figure 5
Figure 6
[ NOTE ]
Primary cartridge filter operation
1.
Solenoid valve for filter cleaning
2.
Filter cartridges
3.
Timer
The filtering cartridges (2) serve the purpose of filtering the
intake air. The vacuum cleaner is equipped with solenoid
valves (1) that, by deflecting the air coming out of the blower,
allow for cyclic cleaning of the filtering cartridges (2). The fully
automatic system grants work continuity and is driven by a
cyclic timer (3) that allows to adjust the intervals T0, T1, T2
which define the cleaning cycle.
WARNING!
The factory setting of the cycle intervals is the one
that allows for a better cleaning in the majority of
applications, for this reason the factory setting should
not be modified. If necessary, for heavy applications
(for example, to collect heavy quantities of very thin
dust - more than 3 kg per minute), it is possible to
modify the intervals by following the instructions in
the Service Manual, available at the Manufacturer's
Service Center.
Emergency stopping
Turn the main switch to "0" position.
Emptying the container
WARNING!
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
Before emptying the container, keep the vacuum unit running
for at least three minutes without collecting dust, so that the
filter cleaning automatic system complete its cycle.
1.
Dust container
Release the container (1), then remove and empty it.
Make sure the gasket is in perfect condition and correctly
positioned.
Place the container back in position and secure it again.
8
Figure 7
Figure 8
07/2014

Publicité

loading

Ce manuel est également adapté pour:

Vht446 ic