Assembly
6 Assembly
WArning
Fire hazard - Danger of death!
The use of inadequate insulation material and vapour barriers can
lead to potentially fatal fires.
f
Comply with local fire protection directives and the instruction
sheet for the downlight used.
f
Comply with the regulations and standards applicable to insulation
material and vapour barriers.
f
Do not use highly ignitable insulation material.
f
Use fire-retardant vapour barriers only.
f
Do not use ecological material such as wood, hemp, straw, etc.
f
Do not use any injection insulation materials.
f
Use board-type insulation material only.
1
Measure and drill the false ceiling board (refer to the instruction
sheet for the downlight used).
2
Clean around the edges of the hole/cut-out in the false ceiling
board if necessary.
f Optional: If installing from below, you can use the SpotClip-Tool
(included in packs of 10 pieces only) to prevent the SpotClip-I
from turning over into the celling during installation (diagrams 
and
):
I
- Insert the tool fixing clips into the mounting holes provided on
the inside of the SpotClip-I.
- Turn clockwise slightly to attach the tool to the SpotClip-I.
7