Cool the device initially with use of default settings. Place drinks and food in the
device only when the sufficient cooling capacity is reached.
NOTE!
The temperature value displayed on the digital display is the value measured
near the temperature sensor and is used for the compressor control.
Digital temperature controller
The temperature controller is located on the back of the device.
2
1
1
2
3
4
5
6
7
LED indicators
LCD indicator for compressor:
The indicator illuminates during the cooling mode, is off when the temperature
in the cooling chamber is stable, and flashes during the activation delay mode.
LCD indicator for defrosting:
The indicator illuminates during the defrosting process, is off after defrosting,
and flashes during the defrosting delay mode.
Temperature decreasing button
Temperature increasing button
LCD indicator for compressor
LCD indicator for defrosting
Illumination button
Settings control/saving button (SET)
Digital display
4
3
7
5
6
- 31 -