Télécharger Imprimer la page

Exquisit EKC801-5Z Instructions D'utilisation Et D'installation page 25

Publicité

ELECTRICAL CONNECTION
• The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The data of connection necessary are on the stickers place on the hob casing near the
connection box.
• The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
• The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or even.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
230V~ 50/60Hz
400V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put a bridge between terminal 1 and 2.
Attach the earth to the terminate "earth", the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase
400V~2P+N
Attach the earth to the terminate "earth", the neutral N to terminal 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution!
Frequent loosening and screwing of the screws on the connection box risks
damaging the efficiency of the tightness once screwed. It is therefore
advisable to keep screwing and unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.
4 weeks after installation, be sure to tighten again the screws in the terminal block.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm²
2 Phases + N
4 x 1.5 mm²
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
25
Protection calibre
25 A *
16 A *

Publicité

loading