Cleaning and maintenance
▶ Pull the filter from the appliance.
▶ Clean the surface of the filter with a vacuum cleaner.
▶ Insert the filter back into the appliance.
▶ Reattach the cover.
▶ Insert the plug of the air purifier in the power socket.
▶ Touch the power button
▶ Touch the filter status check/reset button
▶ Wash your hands after cleaning the filter.
5.4
Replacing the filter
The air purifier is equipped with a filter replacement indicator
make sure that the air purification filter is in optimal condition when the
air purifier is operating.
Replace the filter as soon as possible.
NOTICE
The filter is not washable or reusable.
CAUTION
Wear a mask and gloves when cleaning the filter surface and/or replacing
the filter.
CAUTION
Always turn off the air purifier and unplug it from the electrical outlet
before replacing the filter.
▶ Switch off the air purifier and unplug it from the power socket.
▶ Pull the back cover and remove it from the appliance.
▶ Pull the filter from the appliance.
▶ Remove the plastic cover of the new filter ( Figure Fig. 54
"Removing the plastic cover").
▶ Insert the new filter into the appliance.
▶ Reattach the cover.
▶ Insert the plug of the air purifier in the power socket.
▶ Touch the power button
▶ Touch and hold the filter status check/reset button
to reset the filter replacement counter.
▶ Wash your hands after replacing the filter.
Note:
Do not smell the filter as it has collected pollutants from the air.
5.5
Resetting the filter
When the filter lifetime counter reaches 0%, the screen displays the
message "Filter status 0%" reminding the user to replace the filter. The
message disappears when pressing the filter button
displayed again the next time the appliance is turned on.
54
to switch on the appliance.
.
to switch on the appliance.
for 3 seconds
and will be
to
Fig. 59 Message indicating the filter needs to be replaced
The filter can be replaced before the filter lifetime warning is displayed.
The filter lifetime counter needs to be reset manually after its
replacement:
▶ Touch the power button
from the power socket.
▶ Insert the plug in the power socket.
0010043305-001
to turn off the appliance and unplug it
Air 6000 – 6721848696 (2023/01)