Quick Install Guide: PoLRE24/PoLRE48
The PoLRE (Power over Long Reach Ethernet) family of data switches delivers Ethernet
and PoE (Power over Ethernet) over a single pair of telephony grade wire (CAT 3) with 4
times the reach of traditional data switches. With the PoLRE switch customers can
transform their existing voice infrastructure into an IP network with power ideal for IP
device deployment. For complete details refer to the Hardware Installation Guide at
www.nvtphybridge.com.
NOTE: Please see page 3 for important safety instructions
PoLRE24 & PoLRE48 Switch
Installation Details
System Grounding: See Page 5
Location and Regional Specifications:
PoLRE kan installeres overalt indendørs undtagen i Finland, Norge og
Sverige, hvor i disse tre nordiske lande den skal installeres på et sted
med begrænset adgang.
PoLRE kan installeres innendørs i alle land unntatt Finland, Norge og
Sverge. I disse tre nordiske landene må den installeres på et sted med
begrenset tilgang.
Space Requirements:
1.
Select a standard 19" equipment rack or, for a standalone installation, a flat, stable surface capable of supporting the size and weight of
the PoLRE, its installable components and cabling.
2.
Ensure that you have enough rack space for all equipment. Shelves and rear supporting brackets are not mandatory.
Location Requirements:
Power - The PoLRE switch must be placed within 6 feet of an available power source. Do not use an extension cord to connect the equipment to a
power outlet.
Downlink – The Phylinks can be installed up to 1,200ft (365m) away from the PoLRE switch.
Installation procedures will be trouble‐free if you ensure that the following items are available before you begin:
The PoLRE switch, all cables and accessories you received in the PoLRE package.
All PhyLinks required for connecting the IP endpoint devices, provided with the product package according to the quantity ordered.
SFP transceiver modules for the Gbic uplink trunks if connecting over fiber.
Fiber optic LAN cables for the Gbic uplink trunks (user-supplied) if connecting over fiber.
Standard CAT5e copper LAN cables for the GbE uplink trunks (user‐supplied).
Standard CAT3 unshielded single twisted pair cables, 24 AWG, for the downlink ports (user-supplied).
Serial console cable for the CONSOLE port, provided with the product package.
Standard CAT5e or CAT-6 Ethernet LAN cable for the MGMT port. Optional, only if out-of-band management is required (user‐supplied).
Protective ground cable (user‐supplied).
888.901.3633 | +44 (0) 208 977 6614 |
www.nvtphybridge.com
The PoLRE can be installed in any indoor location in all countries
except in Finland, Norway and Sweden, where, in these 3 Nordic
countries, it must be installed in a restricted access location.
PoLRE kan installeras på valfri plats inomhus i samtliga länder utom
Finland, Norge och Sverige; i dessa nordiska länder måste den
installeras på en plats med begränsad åtkomst.
Copyright 2024 NVT Phybridge | 413-0002-F |
PoLRE 24-Port Switch
PoLRE 48-Port Switch
PoLRE Package Includes:
1 x PoLRE24- or 48-port Unit
1 x Rackmount Bracket Kit
1 x Console Cable
1 x Power Cable
PhyLink Package Includes:
6 x PhyLinks
Page
| 1

Publicité

loading

Sommaire des Matières pour NVT Phybridge PoLRE24

  • Page 1 For complete details refer to the Hardware Installation Guide at PoLRE 48-Port Switch www.nvtphybridge.com. NOTE: Please see page 3 for important safety instructions PoLRE24 & PoLRE48 Switch PoLRE Package Includes: 1 x PoLRE24- or 48-port Unit • 1 x Rackmount Bracket Kit • 1 x Console Cable •...
  • Page 2 NOTE: You can daisy-chain the units together while they are up and running or power them up afterward. • Facing the rear of the units, install the DC cables (available through NVT Phybridge) as follows: NOTE: To fit properly, the DC cable must be inserted into the DC input/output connector with its hairpin clip on top.
  • Page 3 The usage is: pal-set-sys-ip mgmt <IPADDRESS> <NETMASK> <BROADCAST> You will be prompted to confirm this information. Refer to the CLI section of the administration guide for more information. 888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com Copyright 2024 NVT Phybridge | 413-0002-F | Page...
  • Page 4 Selleks, et vältida riski ning tulekahjuoht, vaheta kaitse sama tüüpi ja hinnang. ETTEVAATUST: Maapind kõrv on peamine Maa terminal peab olema püsivalt ühendatud maaga. 888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com Copyright 2024 NVT Phybridge | 413-0002-F | Page...
  • Page 5 Aby ste zabránili nebezpečenstvu výbuchu alebo požiaru, vymeňte poistku rovnakého typu a typu. UPOZORNENIE: Uzemňovacia svorka je hlavná zemniaca svorka, ktorá musí byť trvalo pripojená k uzemneniu. 888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com Copyright 2024 NVT Phybridge | 413-0002-F | Page...
  • Page 6 An Insulated wire, #5 (13mm2) to #14 (2mm2) AWG, with green and yellow stripes • Connected to the grounding stud on the back of the cabinet. 888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com Copyright 2024 NVT Phybridge | 413-0002-F | Page...
  • Page 7 The NVT Phybridge Technical Support Group is available to assist you with product installation, configuration, monitoring and troubleshooting procedures. Should you experience trouble with this equipment or for repair or warranty information, please contact NVT Phybridge Inc. at +1 905.901.3633 or support@nvtphybridge.com.