Winemaster C50S(SR) USER MANUAL
Red light
= cold mode engaged (compressor working)
Red light
= Not used
Red light
= defrost
Red light
= heat mode engaged (resistance)
STANDBY MODE
AUTOMATIC DEFROST
The program of the thermostat from model C50S/SR will run an automatic defrost time several times a day. During this
position, the compressor stops and only the fan in the cellar is functionning.
The condensate water produced during this period will b evacuated through the tube.
5. POSITIONING OF THE WINEMASTER
The WINEMASTER should be installed into a wall with one side of the unit facing the interior of the cellar and the
other side facing the exterior of the cellar on the other side of the wall. This means that the exterior side of the unit
must be accessible from outside of the cellar - see item 6 "WINEMASTER Wall Installation." This allows for the pro-
duction of cool air within the cellar by keeping all warm components on the exterior side of the wall.
16
- Stanby mode : maintain a 3 seconds pressure on button 1. The compressor stops.
The thermostat indicates « OFF » and also the cellar temperature.
-
To come back, maintain again a 3 seconds pressure on button 1.
-
The thermostat indicates « ON » during 1 second.
-
ceiling
10 cm minimum
CELLAR
SCHEMA DE PRINCIPE
WINEMASTER
plancher
03/2009