This manual describes the installation and operation of the Comfort Glow, CGWF4000, N35 wood furnace. This furnace
meets the 2020 U.S. Environmental Protection Agency's emission limits for wood furnaces. Under specific EPA test
conditions this furnace has been shown to deliver heat at a rate of 15,997 – 53,042 BTU/hr. This furnace achieved a
particulate emissions rate of 0.13 lb/mmBtu when tested to method CSA B415.1-10 (*and an overall efficiency of 70%).
The maximum overall heat output of this furnace was tested to be 65,258 Btu/hr.
Combustible:
Flue Pipe Diameter:
Flue Pipe Type: (Standard, Single Wall, or
Double Wall):
Minimum Chimney Height:
Maximum Log Length:
Electrical:
Dimensions
Assembled Height x Width x Depth:
Combustion Chamber:
Width x Depth:
Volume:
Cubic Feet:
Door Opening: Width x Height:
• HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.
• DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
• DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
• DO NOT BURN GARBAGE, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
• ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
• YOUR CHIMNEY MUST BE INSPECTED PRIOR TO THE INSTALLATION OF YOUR NEW WOOD STOVE.
IN ADDITION, YOU SHOULD HAVE YOUR CHIMNEY INSPECTED FOR CREOSOTE DEPOSTS MONTHLY
DURING THE HEATING SEASON AND ANNUALLY INSPECTED AND CLEANED.
Wood
6" (153cm)
Black or Blued Steel 2100°F (650°C) Class "A"
12 ft (3.65 m)
23" (585 mm)
120 Volts, 60 Hz, 6.0 Amps
45" (1143 mm) x 25-3/8" (645 mm) x 54-3/4" (1391 mm)
13.75" (350 mm) x 24" (610 mm)
3.95 Cu Ft.
14" (356 mm) x 13.89" (353 mm)
CAUTIONS:
2