Quick Start Guide
902 VOLTAGE
CONTROLLED AMPLIFIER
Legendary Analog VCA Module
for Eurorack
Controls
(3)
CONTROL MODE (LIN/EXP) rocker switch toggles
(1)
between linear and logarithmic response modes.
FIXED CONTROL VOLTAGE knob allows you to manually
(2)
set a control voltage.
SIG IN input jacks accept audio and control signals over
(3)
cables with 3.5 mm TS connectors. These dual inputs
allow the unit to amplify two signals simultaneously.
SIG OUT output jacks send out amplified audio and control
(4)
signals over cables with 3.5 mm TS connectors.
CONTROL INPUTS accept control voltage signals from
(5)
other modules to change the amplification level.
V 1.0
Power Connection
The 902 VCA comes with the required power cable for connecting
to a standard Eurorack power supply system. Follow these steps
to connect power to the module. It is easier to make these
connections before the module has been mounted into a rack case.
1.
Turn the power supply or rack case power off and
(1)
disconnect the power cable.
2.
Insert the 16-pin connector on the power cable into the
socket on the power supply or rack case. The connector has
a tab that will align with the gap in the socket, so it cannot
be inserted incorrectly. If the power supply does not have
(2)
a keyed socket, be sure to orient pin 1 (-12 V) with the
red stripe on the cable.
3.
Insert the 10-pin connector into the socket on the back of
the module. The connector has a tab that will align with the
(4)
socket for correct orientation.
4.
After both ends of the power cable have been securely
attached, you may mount the module in a case and turn on
(5)
the power supply.
Installation
The necessary screws are included with the module for mounting
in a Eurorack case. Connect the power cable before mounting.
Depending on the rack case, there may be a series of fixed holes
spaced 2 HP apart along the length of the case, or a track that
allows individual threaded plates to slide along the length
of the case. The free-moving threaded plates allow precise
positioning of the module, but each plate should be positioned in
the approximate relation to the mounting holes in your module
before attaching the screws.
Hold the module against the Eurorack rails so that each of the
mounting holes are aligned with a threaded rail or threaded plate.
Attach the screws part way to start, which will allow small
adjustments to the positioning while you get them all aligned.
After the final position has been established, tighten the
screws down.

Publicité

loading

Sommaire des Matières pour Behringer 902 VOLTAGE

  • Page 1 Quick Start Guide 902 VOLTAGE Power Connection CONTROLLED AMPLIFIER The 902 VCA comes with the required power cable for connecting to a standard Eurorack power supply system. Follow these steps to connect power to the module. It is easier to make these Legendary Analog VCA Module connections before the module has been mounted into a rack case.
  • Page 2 902 VOLTAGE CONTROLLED AMPLIFIER Quick Start Guide Conexión eléctrica Connexion électrique Controles Réglages (ES) (FR) El 902 VCA viene con el cable de alimentación necesario para Le 902 VCA est livré avec le câble d’alimentation requis pour la conectarse a un sistema de suministro de energía Eurorack connexion à...
  • Page 3 902 VOLTAGE CONTROLLED AMPLIFIER Quick Start Guide Netzanschluss Conexão de força Bedienelemente Controles (DE) (PT) Der 902 VCA wird mit dem erforderlichen Stromkabel für den O 902 VCA vem com o cabo de alimentação necessário para Anschluss an ein Standard-Eurorack-Stromversorgungssystem conectar a um sistema de fonte de alimentação Eurorack padrão.
  • Page 4 902 VOLTAGE CONTROLLED AMPLIFIER Quick Start Guide Connessione di alimentazione Stroomaansluiting Controlli Bediening (IT) (NL) Il 902 VCA viene fornito con il cavo di alimentazione necessario per De 902 VCA wordt geleverd met de benodigde voedingskabel voor il collegamento a un sistema di alimentazione Eurorack standard.
  • Page 5 902 VOLTAGE CONTROLLED AMPLIFIER Quick Start Guide Strömanslutning Podłączenie zasilania Kontroller Sterownica (SE) (PL) 902 VCA levereras med den strömkabel som krävs för att ansluta Model 902 VCA jest dostarczany z wymaganym kablem till ett vanligt Eurorack-nätaggregat. Följ dessa steg för att zasilającym do podłączenia do standardowego systemu zasilania...
  • Page 6 902 VOLTAGE CONTROLLED AMPLIFIER Quick Start Guide Specifications Controls Control Mode Rocker switch Linear / exponential, switchable 1 x rotary knob Fixed Control Voltage 0 - 6 V, selectable Signal Connections Signal in 2 x 3.5 mm TS jack, mono Impedance 9 kΩ...
  • Page 7 Midas, Klark Teknik, zijn eigendom van hun respectievelijke eigenaren. Midas, Klark Teknik, TC Electronic, TC Helicon, Behringer, Bugera, Oberheim, Auratone, propriétaires respectifs. Midas, Klark Teknik, Lab Gruppen, Lake, Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, TC Helicon,...
  • Page 8 Wszystkie znaki towarowe są własnością ich odpowiednich właścicieli. Midas, Klark Teknik, Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, TC Helicon, Behringer, Bugera, Oberheim, Auratone, Aston Microphones i Coolaudio są znakami towarowymi lub zastrzeżonymi znakami towarowymi firmy Music Tribe Global Brands Ltd.
  • Page 9 902 VOLTAGE CONTROLLED AMPLIFIER Quick Start Guide Hereby, Music Tribe declares that this product is in compliance with Directive 2014/30/EU, Directive 2011/65/EU and Amendment 2015/863/EU, Directive 2012/19/EU, Regulation 519/2012 REACH SVHC and Directive 1907/2006/EC. Full text of EU DoC is available at https://community.musictribe.com/...
  • Page 10 902 VOLTAGE CONTROLLED AMPLIFIER Quick Start Guide...
  • Page 11 We Hear You...