WARNING
!
•
Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or
removed.
•
Turn off gas and electrical power before servicing the appliance.
•
Appliance may be hot. Do not service until appliance has cooled.
•
Do not use abrasive cleaners
symptom
Main burner fl ame is a
Blockage in vent.
blue, lazy, transparent
fl ame.
(This is not applicable
in outdoor appliances)
Incorrect installation.
Flames are consistently
Appliance is over-fi red or under-
too large or too small.
fi red.
Carboning occurs.
IGNITOR
(SPARK)
INSERT
SENSOR
PHOTO
OF VALVE
HERE
Air shutter improperly adjusted.
Carbon is being
Air shutter is blocked.
deposited on glass,
Flame is impinging on the glass,
logs, rocks, media, or
logs, rocks, media or combus-
combustion chamber
tion chamber.
surfaces.
White / grey fi lm forms.
Sulphur from fuel is being depos-
ited on glass, logs, or combus-
tion chamber surfaces.
Exhaust fumes smelled
Appliance is spilling.
in room, headaches.
(This is not applicable in outdoor
appliances).
14.0 troubleshooting (electronic)
problem
-
-
-
Pressure
Natural Gas
(inches)
Inlet
(minimum 4.5")
PILOT
TUBE
Outlet
-
-
-
-
-
-
-
-
-
-
-
-
-
-
troubleshooting (electronic)
test solution
Remove blockage. In really cold conditions, ice buildup may occur
on the terminal and should be removed as required. (To minimize this
from reoccuring, the vent lengths that pass through unheated spaces
(attics, garages, crawl spaces) should be wrapped with an insulated
mylar sleeve).
Refer to "venting" section to ensure correct installation.
Check pressure readings:
Inlet pressure can be checked by turning screw (A) counter-clock-
wise 2 or 3 turns and then placing pressure gauge tubing over the
test point. Gauge should read as described on the chart below.
Check that main burner is operating on 'HI'. Outlet pressure can be
checked the same as above using screw (B). Gauge should read as
described on the chart below. Check that main burner is operating
on 'HI'. After taking pressure readings, be sure to turn screws
clockwise fi rmly to reseal. DO NOT OVER TORQUE.
Leak test with a soap and water solution.
Natural Gas
(millibars)
*7"
17.4mb
(minimum 11.2mb)
3.5"
8.7mb
*Maximum inlet pressure not to exceed 13" w.c.
Return air shutter to specifi ed opening, see "venturi adjustments"
section in the installation manual.
Ensure air shutter opening is free of lint or other obstructions.
Ensure the media is positioned correctly in the appliance.
Open air shutter to increase the primary air.
Check the input rate: check the manifold pressure and orifi ce size as
specifi ed by the rating plate.
Ensure door gaskets are not broken or missing and the seal is tight.
Ensure vent liners are free of holes and well sealed at all joints.
Check that minimum rise per foot (meters) has been adhered to for
any horizontal venting.
Clean the glass with a recommended gas fi replace glass cleaner. DO
NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may become
permanently marked.
Check door seal.
Check for exhaust damage.
Check that venting is installed correctly.
Room is in negative pressure; increase fresh air supply.
Propane
Propane
(inches)
(millibars)
13"
32.4mb
(minimum 11")
(minimum 27.4mb)
10"
24.9mb
W415-2884 / A / 09.21.20
EN
43