Recommendations and
EN
suggestions
• The Instructions for Use apply to
several versions of this appliance.
Accordingly, you may find descrip-
tions of individual features that do
not apply to your specific appliance.
• The manufacturer will not be held
liable for any damages resulting from
incorrect or improper installation.
• The minimum safety distance
between the cooker top and the
extractor hood is 650 mm (some
models can be installed at a lower
height, please refer to the para-
graphs on working dimensions and
installation).
• Check that the mains voltage cor-
responds to that indicated on the
rating plate fixed to the inside of
the hood.
• For Class I appliances, check that
the domestic power supply guaran-
tees adequate earthing.Connect the
extractor to the exhaust flue through
a pipe of minimum diameter 120
mm. The route of the flue must be
as short as possible.
• Do not connect the extractor hood to
exhaust ducts carrying combustion
fumes (boilers, fireplaces, etc.).
• If the extractor is used in conjunction
with non-electrical appliances (e.g.
gas burning appliances), a sufficient
degree of aeration must be guaran-
teed in the room in order to prevent
the backflow of exhaust gas. The
kitchen must have an opening com-
municating directly with the open air
in order to guarantee the entry of
8
clean air. When the cooker hood is
used in conjunction with appliances
supplied with energy other than
electric, the negative pressure in the
room must not exceed 0,04 mbar
to prevent fumes being drawn back
into the room by the cooker hood.
• The air must not be discharged into
a flue that is used for exhausting
fumes from appliances burning gas
or other fuels (not applicable to
appliances that only discharge the
air back into the room).
• In the event of damage to the power
cable, it must be replaced by the
manufacturer or by the technical
service department, in order to
prevent any risks.
• If the instructions for installation
for the gas hob specify a greater
distance specified above, this has to
be taken into account. Regulations
concerning the discharge of air have
to be fulfilled.
• Use only screws and small parts in
support of the hood.
Warning: Failure to install the
screws or fixing device in accord-
ance with these instructions may
result in electrical hazards.
• Connect the hood to the mains
through a two-pole switch having
a contact gap of at least 3 mm.
Use
• The extractor hood has been de-
signed exclusively for domestic use
to eliminate kitchen smells.
• Never use the hood for purposes
other than for which it has been
designed.