LED flashes every second and alarm sounds:
LED flashes every 8 seconds:
LED flashes every 40 seconds and a short
alarm tone sounds:
Installation (Fig.7) :
1: Dowel
2. Mounting base
3. Holes for screws for fixing
4: Screw
5: Retainer of the bayonet connection
Attention:
Before drilling the mounting holes, make sure that there are no gas, electricity or water pipes at the
drilling location that could be damaged by this!
Attention
: The device is only ready for operation if the case is properly attached to the mounting base. Otherwise
the battery is deactivated and the smoke alarm is not ready for use.
Since smoke rises to the top and spreads horizontally, install the smoke detector in the middle of the room if possible.
Observe a minimum distance of 0.5m from the side wall and 0.6m from the corner of the room, as well as a maximum
installation height of 6m (see Fig.6).
Remove the mounting plate located on the back of the housing by turning it counterclockwise.
Select an easily accessible installation location, as the smoke alarm detector must be checked weekly for
proper functioning!
Hold the mounting base to the position on the ceiling where you want to attach the unit. Then draw the holes
for the drill holes on the ceiling with a pencil.
Then drill two holes (Ø 6mm). Take the two plugs included in the delivery and insert them into the drilled
holes.
Screw the mounting base to the ceiling. The screws are included in the delivery.
Attach the housing to the mounting base by turning it clockwise until it clicks into place.
Reasons for a false alarm:
Water and kitchen vapours
very high air humidity
very dusty air
very heavy smoke from cigarettes or cigars, for example
Behavior in case of fire:
In case of fire, go outside immediately and call the fire brigade for help! Do not waste time by putting on clothes or
carrying personal belongings. Inhaling the dangerous smoke gas will cause severe damage to your body, which can
lead to unconsciousness and subsequent death!
Further fire protection measures:
Creation of an escape plan
TEST button is pressed or the alarm has been triggered by
smoke.
The device is in the silent mode
Battery is low.