GB
FSP
Problem
E Material accumula-
tion concentrated in
the middle
F Spray pattern
moved to one side
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
**See Chapter: "Intended use" in Instruction manual part 1!
***For troubleshooting: read chapter: "Commissioning"!
****For troubleshooting: read chapter: "Maintenance"!
If necessary, contact our service staff, see last page.
II/ 12
Cause
Too much material application
Working pressure (flow pres-
sure) too low
Viscosity is too high
Dirty or deformed holes on the
flanges of the air cap
Remedy
Use smaller nozzle set Reduce
paint quantity (item 03):
Decrease
material
(item 18):
Increase working pressure (flow
pressure)
Observe
*
working pressure
Decrease viscosity or increase
material pressure (item 18)
****
Clean
or replace complete
nozzle set (see Figure 3a-c)
pressure
maximum
***

Publicité