CAUTION / PRECAUCIÓN / MISE EN GARDE
HOT! This system can dispense near boiling water. Care and
supervision should be taken to avoid scalding.
¡CALIENTE! Este sistema puede suministrar agua casi
hirviendo. Se debe tener cuidado y usarlo bajo supervisión
para evitar quemaduras.
BRÛLANT! Ce système peut distribuer de l'eau bouillante.
Des précautions doivent être prises et une supervision
assurée pour éviter les brûlures.

Publicité

loading

Sommaire des Matières pour InSinkErator HWT200-F1500S

  • Page 1 Des précautions doivent être prises et une supervision assurée pour éviter les brûlures. Instant Hot Water Tank Installation, Care & Use Tanque de agua caliente instantánea Instalación, mantenimiento y uso Réservoir d’eau chaude instantanée Installation, entretien et utilisation HWT200-F1500S HWT200...
  • Page 2 CAUTION: Personal Injury/Property Damage. This tank is a non-pressurized tank. DO NOT modify this system. DO NOT close vent tube or connect other types of dispensers or valves to the tank. Use only the InSinkErator dispenser supplied. •...
  • Page 3 Inspeccione el sistema con regularidad. Si hay señales de fugas de agua, cierre el suministro de agua y comuníquese con NO cierre el tubo de ventilación ni conecte otro tipo de dispensadores o válvulas al tanque. Use sólo el dispensador InSinkErator InSinkErator.
  • Page 4 à l’origine ou à la sortie du système. • Veuillez communiquer avec InSinkErator s’il manque un collet à l’un ou l’autre des raccords (voir les coordonnées figurant au dos du manuel).
  • Page 5 InSinkErator Hot Water Dispenser Options (sold separately, various models available) Componentes del tanque de agua caliente y sistema de filtración Opciones del dispensador de agua caliente InSinkErator (se venden por separado) Composants du réservoir d’eau chaude et du système de filtration Éléments optionnels pour le robinet d’eau chaude InSinkErator (vendus séparément)
  • Page 6 Overview of Complete Setup Descripción general de la configuración completa Présentation générale de l’installation complète ENGLISH Note: Install InSinkErator hot water dispenser. See dispenser Installation, Care and Use manual (not included) for details. NOTICE: Property Damage. Do not pinch or break copper or braided tubing.
  • Page 7 ₈ ¼" ENGLISH ENGLISH (3mm) ¼" WARNING. (Personal Injury) Do not locate NOTICE: Property Damage. Pinched or (3mm) filter above an outlet or other electrical blocked water lines may cause damage to device. Install head and bracket so that the water tank. Check to make sure tubes connections require no stretching, kinking are connected correctly and are pushed or pinching of tubing.
  • Page 8 HWT200- F1500S ENGLISH ENGLISH NOTICE: Property Damage. Tube runs need NOTICE: Property Damage. Top surface to form to the cabinet’s contours to allow of cartridge will be flush with bottom of the storage space with no sharp bends. Tubes need filter and filter-label will face forward when clean, perpendicular, burr-free cuts to ensure fully engaged.
  • Page 9 ENGLISH CAUTION: If the water in the tank continuously boils or steam/spitting comes out of the spout turn the ENGLISH temperature control down until the boiling and/or steam/spitting stops. NOTICE: Property Damage. Tank must WARNING: Scalding Hazard. The be located within 15.7” (400 mm) of tank dispenses steaming hot dispenser and within 30”...
  • Page 10 If there is any discoloration or rusty appearance, unplug and drain unit as described in the Seasonal Storage/Drainage section on this page HWT200-F1500S is certified by IAPMO R&T against of the manual. NSF/ANSI standard 42 and CSA B483.1 for the reduction of claims specified on the performance data sheet.
  • Page 11 You may also notify us at: InSinkErator Service Después de la vida útil recomendada, el filtro debe desecharse según las normas y reglamentos vigentes.
  • Page 12 PROBLEMAS DE FILTRACIÓN de serie de su Producto de InSinkErator y, si es necesario y se solicita, una confirmación escrita de: (a) la fecha que figura en su recibo de instalación, o (b) la fecha que figura en su recibo de compra.
  • Page 13 InSinkErator. Le modèle HWT200-F1500S est certifié par l’IAPMO R&T pour la AUTRES CONSIDÉRATIONS CONCERNANT L’UTILISATION DU SYSTÈME DE FILTRATION : conformité aux normes NSF/ANSI 42 et à la norme CSA B483.1 concernant les revendications de réduction des substances spécifiées sur la fiche des...
  • Page 14 Cette garantie limitée est fournie par InSinkErator LLC, (« InSinkErator », « Fabricant », « nous », « nos » ou « notre ») au consommateur original propriétaire du produit InSinkErator avec lequel cette garantie limitée est fournie (le « Produit InSinkErator ») et tout propriétaire subséquent de la résidence dans laquelle le Produit a originalement été...
  • Page 15 ®/TM © 2022 InSinkErator. All rights reserved. InSinkErator InSinkErator Canada InSinkErator se réserve le droit, à son entière discrétion, d’apporter en tout temps des 1250 International Drive 66 Leek Crescent améliorations ou des modifications aux caractéristiques techniques, et ce, sans préavis ou...