6
2. Battery temperature sensor connection
Pin definition of Battery temperature sensor side
1
8
Pin
1 2 3 4 5 6 7 8
Pin Definition
Pin definition of COM port of inverter side
For Battery temperature sensor
connection
Battery temperature sensor wiring procedures
Connect one side of communication cable to the inverter COM port (PlN 19 and
Pin 30), connect another side to RJ45 terminal (Pin 3 and Pin 8) and insert it into the RJ45
connector, then insert the battery temperature sensor into the RJ45 connector.
1
2
3
X
X
BMS_GND
Pin
19
30
Inverter
COM port
4
5
6
X
X
X
Pin assignment
BMS_GND
TEMP_BAT
RJ45
connector
Click!
7
8
X
TEMP_BAT
65