10. It is safe to leave water in the pressure tank when the steam cleaner is not
in use. If it is for an extended period of time (months) then it is best to flush
out the remaining water. To do so, follow the water removal instructions
as outlined in the maintenance of the boiler section.
THIS MODEL IS PROVIDED wITH THE
FOLLOwING FEATURES
RED CONTROL LIGHT (4)
A red warning light signals that the water in the tank has been emptied. A buzzer will
sound in case you did not see the red light. A continuous humming sound from the
pump comes before this. At this point switch off the steam cleaner by turning it to
position "0," fill the tank with water and switch back on.
STEAM REGULATION (ON HANDLE)
With the steam delivery adjustment, it is possible to select the steam quantity that
you wish during your cleaning from minimum to maximum.
PRESSURE GAUGE (8)
The pressure gauge indicates the operating pressure of the steam cleaner. If the
needle is in the green section, the product is operating normally. If the needle
is continuously in the red section, reduce amount of steam being used, if this does
not correct the problem the steam cleaner may require service. Please contact
the place of purchase for service.

USING THE ACCESSORIES

CONNECTING THE ACCESSORIES
Insert the plug at the opposite end of the steam gun/hose (11) to the connecting
outlet (10) all the way, making sure it cannot be pushed in further. Connect the
handle of the steam gun (11) to the extension tubes (12), pressing the locking but-
ton lightly until the button snaps in. All the accessories are connected the same way.
The angle adapter (16) is used for the rectangular (13) and triangular (14) brush
in the following way: hold the brush in one hand with the bristles pointing down while
with the other hand inserts the angle adapter into the brush pointing it downward.
After this, turn the angle adapter 180º so that the line on the angle adapter and
the dot on the brush line up. When the line and the dot line up, you can adjust
the grey lever to the middle position (locked) to lock the brush so that it cannot
move, or to the position closest to you (rotate) to allow for the brush head to
rotate. To remove the brush, make sure the grey lever is in the position furthest
from you (assemble) and make sure the line on the adapter and the dot on the
brush line up. Rotate 180º to remove.