MAINTENANCE OF THE BOILER
To maintain your steam cleaner in good condition and to ensure constant perfor -
mance, we recommend that you periodically clean the boiler once or twice a year
depending on the hardness of the water:
CLEANING INSTRUCTIONS
ATTENTION: Before cleaning the boiler with the supplied de-scaling powder, please
make sure that the boiler is at room temperature, that it has not been used for at
least 8 hours, and that the boiler is disconnected from the power source.
1. Turn the steam cleaner over. Unscrew and remove the bolt (remove the cap
first) with the tool provided and eliminate all the water remaining in the boiler.
LEAVE THE UNIT UPSIDE DOWN.
2. Completely dissolve the contents of the single package of de-scaling powder
in 2 cups (0.5l) of water.
3. Pour the solution into the boiler. (Attention: Do not put the dissolved solu-
tion into the water container). Place the bolt back on, and turn over on its
right side.
4. Leave the solution in the boiler for 3 hours with the bolt screwed on and leave
the product on its right side.
5.
Remove the bolt, and completely empty the contents of the boiler and rinse
three or four times with water in order to eliminate possible residues of scale.
6.
It is a good idea to spray the first steam onto a cloth and not directly on any
surface since there still may be scale in the system.
ATTENTION: IT IS NOT RECOMMENDED THAT yOU USE ANy OTHER CHEMICAL TO
CLEAN THIS PRODUCT. DOING SO wILL AUTOMATICALLy VOID THE wARRANTy.
ATTACHMENT COUPLINGS
If the attachment connections dry up after intensive use, put a small amount of
lubricant (Vaseline) around the O-rings on the male attachment.
TECHNICAL DESCRIPTION
120V Power
Cold water tank capacity
Working pressure
Safety valve
09
1400W
2L
4bar
Yes
www.sylvane.com (800) 934-9194