5. OPERATING INSTRUCTIONS
It is recommended that you installed your appliance in a place where the ambient temperature is
between 16-38°C. If the ambient temperature is above or below recommended temperatures, the
performance of the unit may be affected and it may not be possible to obtain temperature between 5-
12°C/12-20°C. The ambient temperature has an impact on the interior temperature and humidity of your
cellar. For optimal operation, the settings of your cellar are made for ambient temperatures of 23°C to 25°C.
Temperature setting
1. ON/OFF button press 3s to turn on/off.
2. Press for °C/°F temperature unit selection.
3. Compartment selector key (bottom or top).
4. Lower compartment temperature display.
5. Display of the temperature of the upper compartment.
6. Key to increase the set temperature by 1°C.
7. Key to decrease the set temperature by 1°C.
6+7. Press 3 sec buttons to lock or unlock the control panel.
8.Lighting on/off key.
Temperature selection
The wine cooler has two temperature zones. The temperature setting of upper zone is adjustable with the
range 5-12°C, which is ideal for storing sparkling and white wines. The temperature setting of lower zone
is adjustable with the range 12-20°C, which is ideal for storing white and red wines.
NOTE: both two zones temperature could be set at 12ºC, and it is workable at the same time. But for
optimal performance, once one zone is set at 12ºC, we suggest another setting for the other zone
with 3°C difference at minimum (example: 5°C upper and 8°C lower). Maximum temperature
difference between both compartments is 10°C. Always set cooler temperature in the upper
compartment and warmer temperature in the lower compartment (example: 5°C upper and 15°C
lower).
• To select the temperature zone, press (3) once, upper zone will flash, (3) key pressing again to switch
it to lower zone. Setting temperature could only be set under display flash status.
• You can touch key "+" (6) and key "-" (7) to set the internal temperature for the selected zone. The
degrees indicators will appear in the display window marked
• When the unit is plugged in for the first time, the LED readouts will show the original temperature set