Télécharger Imprimer la page

Abus TVAC25010 Manuel Utilisateur page 18

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6.2 Cleaning
Wipe the product with a clean, dry cloth. If the device is very dirty, you can moisten the cloth with
lukewarm water.
Make sure that no liquids can enter the equipment as the device can be destroyed.
Never use chemical detergents as they could attack the surface of the device
7. Disposal
Devices with this marking should not be put in the household garbage. Dispose of the
product at the end of its lifetime according to the applicable regulations.
8. Pin-Assignment
PIN
Symbol
1
Rx+
2
Rx-
3
TX+
4
+VDC
5
+VDC
6
TX-
7
-VDC
8
-VDC
Warning:
Pin 7 and 8 should not be shorted to Ground.
9. Technical data
Type number
Inputs
Input power
Input power
Outputs
Output voltage
Output power
Data rate
Connection cable length
Operation temperature
Operation Humidity
Dimensions (BxHxT)
Weight
RJ45 Input
(data and power)
Description
Data receive
Data receive
Data transmission
Feeding power (+)
Feeding power (+)
Data transmission
Feeding power (-)
Feeding power (-)
RJ45 Output
(only data)
Symbol
Rx+
Rx-
TX+
Data transmission
U
U
TX-
Data transmission
U
U
TVAC25010
1x RJ-45 (PoE, data & power)
Typical: -48 VDC (-42 VDC – -60 VDC)
12W @ 48 VDC
1x RJ-45 (Data); 1x DC-OUT (5,5 x 2,1 mm)
12 VDC / 1A
12 W
10/100 MB/s
30 cm per Output
-10°C - +60°C
max. 90%, RH
86 mm x 36 mm x 76 mm
110 g
15
English
Description
Data receive
Data receive
Not connected
Not connected
Not connected
Not connected

Publicité

loading