TROUBLESHOOTING TESTS
NOTE: These checks are done with the dryer
unplugged or disconnected from power.
TEST #1 Supply Connections
This test assumes that proper voltage is present
at the outlet, and for U.S. installations, a visual
inspection indicates that the power cord is
securely fastened to the terminal block (electric
dryer) or wire harness connection (gas dryer).
Figure 2. Remove the cover plate.
ELECTRIC DRYER (U.S. Installations):
1. Unplug dryer or disconnect power.
2. Remove the cover plate from the top right
corner of the back of the dryer. See figure 2.
3. With an ohmmeter, check for continuity
between the neutral (N) terminal of the plug and
the center contact on the terminal block. See
figure 3a.
If there is no continuity, replace the power
cord and test the dryer.
If there is continuity, go to step 4.
4. In a similar way, check which terminal of the
plug is connected to the left-most contact on the
terminal block and make a note of it. This will be
L1 (black wire) in the wiring diagram. See figure 3a.
Power Cord
N
Plug
COM
Figure 3a. Plug-to-terminal connections
for electric dryer.
Remove
Screw
Cover
Plate
Terminal Block
L1
PAGE 12
If neither of the plug terminals have continuity
with the left-most contact of the terminal block,
replace the power cord and test the dryer.
5. Access the machine control electronics
without disconnecting any wiring to the control
board. See Accessing & Removing the Electronic
Assemblies, page 21.
6. With an ohmmeter, check for continuity
between the L1 terminal of the plug (found in step
4) and P9-2 (black wire) on the machine control
board. See figure 15, page 23.
If there is continuity, go to step 7.
If there is no continuity, check that wires to the
terminal block are mechanically secure. If so,
replace the main wire harness and test the dryer.
7. Check for continuity between the neutral (N)
terminal of the plug and P8-3 (white wire) on the
machine control board.
If there is continuity, go to step 8.
If there is no continuity and the mechanical
connections of the wire are secure, replace the
main wire harness.
8. Visually check that the P5 connector is
inserted all the way into the machine control
electronics.
9. Visually check that the user interface and
housing assembly is properly inserted into the
front console.
10. If both visual checks pass, replace the
user interface and housing assembly.
11. Reassemble all parts and panels.
12. Plug in dryer or reconnect power.
13. Activate the Service Diagnostic mode per
procedure on page 2. Then activate the User
Interface/Control System test and verify the repair
by completing the Buttons and Indicators test per
procedures on page 5.
14. If indicators still do not light, the machine
control electronics has failed:
Unplug dryer or disconnect power.
Replace the machine control electronics.
Reassemble all parts and panels.
Plug in dryer or reconnect power.
Activate the Service Diagnostic mode per
procedure on page 2. Then activate the User
Interface/Control System test and verify the repair
by completing the Buttons and Indicators test per
procedures on page 5.