Loosen the swivel nut, pull out the rubber stopper
out of the AC connector. Scratch the ports of the
3
rubber stopper with a knife.
Plug L1/ L2/ L3/ N/ PE cables into the
5
corresponding ports of the terminal block.
Insert the terminal block and rubber stopper back
7
to the AC connector and tighten the swivel nut.
Remove the dustproof cover from the Grid&EPS
9
port.
11
142
Click!
Outer side
EPS
PE L1 L2 L3 N
GRID
Inner side
4
Pull out the terminal block inside.
6
8
Pull up the latch.
10
Lock the AC connector
with an Allen key.
Screw to tighten
Grid and EPS
cables with an
Allen key.
Allen key
2.5±0.1 N·m
Insert the AC connector
into the Grid&EPS port of
the inverter.
Allen key
2.5±0.1 N·m