Télécharger Imprimer la page

clage Zip HydroTap BCS 20 Instructions D'utilisation Et D'installation page 32

Publicité

Les langues disponibles

Les langues disponibles

Zip HydroTap® G5 BCS 60
4. Installation
EN
A
15. When cleaning is complete, remove the cleaning can and the adapter and reinsert
the filter cartridge.
16. The hot water tank must then be emptied manually. This can be done either via
the fitting or by pressing and holding the green arrow on the display.
17. The tank is then rinsed. The number of rinse cycles is shown in the display. If your
tap is installed above a sink or tableau with a drain, activate the automatic flush
function. If not, you must draw water manually when the corresponding display
appears until the tank is empty.
Note: If the hot water temperature is still above 50 °C after flushing, the tank
must be emptied again.
18. Open the CO
supply.
2
19. A prompt will appear on the display asking you to flush the carbonizer with carbon
dioxide. Tap the green arrow to start the flush. Carbon dioxide then flows through
the appliance for 30 seconds and audibly out of the fitting. The process can be
stopped prematurely as soon as only gas comes out of the fitting.
20. Using a 6 mm Allen key or a large flat blade screw driver to adjust the flow rate of
sparkling water to 1.6 l/min at the carbonation valve.
a. Rotate the adjustment screw "A" clockwise to decrease the flow.
b. Rotate the adjustment screw "A" anti-clockwise to increase the flow.
To measure the flow rate you have set, use a measuring cup or jug and run the spar-
kling water for 15 seconds. (The HydroTap has a default 15 seconds dispense time,
which will help in your flow rate set up.) Multiply the amount of water dispensed in
that 15 seconds by 4 to get your flow rate in litres per minute. 1.6 litres per minute is
the optimum flow rate.
Note: If you adjust the flow rate too high, you will empty the carbonation can of
water leaving only CO
to be dispensed from the tap.
2
Take care NOT to use excessive force during adjustment of the valve.
21. Booster settings appears. Select "No Booster" to continue.
22. The unit will then be in normal operating mode.
23. Check the water flow and the temperature.
24. Register the appliance online at www.clage.com.
32

Publicité

loading

Ce manuel est également adapté pour:

Zip hydrotap g5 bcs 60