4. Installation
Socket
O-Ring
Rubber seal
Locking washer
Triple silicone tube
Quick connector
Flexible hose
warm water (red)
Flexible hose for
mixed water
Flexible hose for
ambient water (blue)
Nut
Triple silicone tube
Cold water &
Boiling water
sparkling water
Steam
Installation Celsius
Note: The tap must not be installed more than 900 mm above the base of the
undersink unit. Failure to do this may result in poor water delivery.
1. Make sure that the tap location will allow water from the tap to fall into a sink or
other basin fitted with a drain to drain away.
2. Cut a 50 mm diameter hole in the worktop / sink at the place where the tap is to be
installed.
3. Pass the hoses down through the 50 mm hole in the worktop / sink and locate the
tap head on its mounting location.
4. From the underside, push first the rubber seal and the sluice plate over the
hoses / cables, then over the threaded rod of the tap fitting. Secure the sluice
plate with the fastening nut. Check the tap head is in the correct position before
tightening up the nut.
Pay attention to the correct position of the O-ring at the socket.
5. Install the flexible hoses for warm, ambient and mixed water according to the
drawing (see left).
6. Connect the cold water connector of the triple silicone tube to the supplied quick
connector and Y adapter.
7. Push the blue and white plastic tubes as far as they will go into the two openings
of the Y adapter.