24. TECHNICAL SPECIFICATIONS
AC INPUT
Input voltage:
Input frequency:
Power factor:
Connection value:
RCD:
Input under voltage protection:
Input overvoltage protection:
DC OUTPUT
Protocol:
Output power:
Output voltage range:
Output current range:
Output overvoltage protection:
Output under voltage alarm:
Voltage stabilized accuracy:
Max. startup overshoot:
Current stabilized accuracy:
Startup Time:
Efficiency:
OPERATING ENVIRONMENT
Operating temperature:
Overtemperature protection:
Operating/ambient temperature:
Storage temperature:
Humidity:
Pressure/Altitude:
25. www.ecotap.nl
3f 400VAC ± 10% + PE
50Hz
Rated output load PF ≥ 0.99
Minimal 3 x 185A
(With a lower available capacity, the charger
can be set lower by software)
Type B
255V ±5V
535V ±5V
Mode 4
1 - 120 kW CCS
200-1000VDC
CCS: 0~250A (400A peak) ,
1000±5V
140V±2V
≤±0.5%
≤±1%
≤±1%
Normally 3s ≤ t ≤ 15s
>96%
-30°C ~ 70°C, derating from 55°C
On temperature >70°C±4°C or <-40°C±4°C,
charger will shut down automatically
-25°- to 60°
- 40°C ~ 85°C
≤ 95% RH, without condensation
79kPa~106kPa/2000m
24-01-23