3. To clean air cap and fluid tip, brush exterior with a
stiff bristle brush. If necessary to clean cap holes,
use a broom straw or toothpick if possible. If a wire
or hard instrument is used, extreme care must be
used to prevent scratching or burring of the holes
which will cause a distorted spray pattern.
PREVENTATIVE MAINTENANCE
Spray Gun Lubrication
1. Apply a drop of GL-1 spray gun lube at trigger
bearing stud and the stem of the air valve. The
shank of the fluid needle where it enters the
packing nut should also be oiled. The fluid needle
packing should be kept soft and pliable by periodic
lubrication.
2. Make sure the baffle and retaining ring threads are
clean and free of foreign matter. Before assembling
retaining ring to baffle, clean the threads
thoroughly, then add two drops of GL-1 spray gun
SPARE PARTS
PART No
SLG-110-1318
SLG-110-25
SLG-210-XX
SLG-310-XX
SLG-40
SLG-401
SLG-402
SLG-450
EC Declaration of Conformity
We, Finishing Brands UK Limited, Ringwood Rd, Bournemouth, Dorset, BH11 9LH, UK, as the
manufacturer of the Spray gun model SLG, declare, under our sole responsibility that the
equipment to which this document relates is in conformity with the following standards or other
normative documents:
BS EN 12100:2010 and BS EN 1953:2013; and thereby conform to the protection
requirements of Council Directive 2006/42/EC relating to Machinery Safety Directive, and;
EN 13463-1:2009, council Directive 94/9/EC relating to Equipment and Protective
Systems intended for use in Potentially Explosive Atmospheres protection level II 2 G X.
Finishing Brands UK Limited,
Ringwood Road,
Bournemouth,
BH11 9LH,
UK.
Tel.No: 01202 571111
Fax No: 01202 581940
Website address: http:// www.finishingbrands.eu
DESCRIPTION
AIR CAP, for 1.3 & 1.8
AIR CAP, for 2.5
FLUID TIP, 1.3, 1.8 or 2.5
NEEDLE, 1.3, 1.8 or 2.5
NEEDLE PACKING
FAN CONTROL
AIR ADJUSTING VALVE
GRAVITY CUP AND LID
D. Smith, General Manager
th
28
4. To clean fluid passages, remove excess material
at source, then flush with a suitable solvent. Wipe
gun exterior with a solvent dampened cloth. Never
completely immerse in solvent as this is
detrimental to the lubricants and packings.
lube to threads.
3. The fluid needle spring and air valve spring should
be coated with a light grease, making sure that any
excess grease will not clog the air passages. For
best results, lubricate the points indicated, daily.
A. Trigger Points
B. Packing
C. Adjusting Valves
D. Baffle/Air Cap Threads
E. Needle adjusting knob and spring (inside knob)
February 2014
Registered office:
Finishing Brands UK Limited,
400, Capability Green,
Luton,
Bedfordshire,
LU1 3AE,
UK.
Registered in England No: 07656273
Vat No: GB 113 5531 50
4
© 2014 Finishing Brands UK Ltd.

Publicité

loading

Produits Connexes pour StartingLine SLG-620