SERVICE AND STORAGE
INFREQUENT SERVICE
If the unit is used infrequently, difficult starting may
result. to eliminate hard starting, run the generator at least 30
minutes every month. Also, if the unit will not be used for
some time, it is a good idea to drain the fuel from the
carburetor and gas tank.
LONG TERM STORAGE
When the generator set is not being operated or is being
stored more than one month, follow these instructions:
1. Replenish engine oil to upper level.
2. Drain gasoline from fuel tank, fuel line and carburetor.
3. Pour about one teaspoon of engine oil through the spark
plug hole, pull the recoil starter several times and replace
the plug. Then pull the starter until you feel the piston is
on its compression stroke and leave it in that position.
This closes both the intake and exhaust valves to prevent
the inside of the cylinder from rusting.
4. Cover the unit and store in a clean, dry place that is well
ventilated away from open flame or sparks.
NOTE: We recommend always using a fuel stabilizer. A
fuel stabilizer will minimize the formulation of fuel gum
deposits during storage. The fuel stabilizer can be added
to the gasoline in the fuel tank, or into the gasoline in a
storage container.
www.powermate.com
SERVICE INFORMATION
CONTACT THE COLEMAN®
POWERMATE® PRODUCT
SERVICE DEPARTMENT AT
1-800-445-1805
www.powermate.com
to obtain warranty service
information or to order
replacement parts or
accessories.
HOW TO ORDER REPLACEMENT PARTS
Even quality built equipment such as the Coleman®
Powermate® electric generator you have purchased, might need
occasional replacement parts to maintain it in good condition
over the years. To order replacement parts, please give the fol-
lowing information:
1.
Model No. and Serial No. and all specifications shown on
the Model No./Serial No. plate.
2.
Part number or numbers as shown in the Parts List
section.
3.
A brief description of the trouble with the generator.
NOTE: If replacement parts are required for the
engine, contact one of the engine manufacturer's service
centers.
Powermate Corporation
4970 Airport Road
P. O. Box 6001
Kearney, NE 68848
1-800-445-1805
www.powermate.com
12
or at
Customer Hotline 1-800-445-1805