Télécharger Imprimer la page
Philips CoreLine Highbay Gen 5 BY122X Manuel D'installation

Philips CoreLine Highbay Gen 5 BY122X Manuel D'installation

Publicité

Liens rapides

CoreLine
Highbay Gen 5
BY122X
indoor
Description
BY122X G5 LED105S SIA H4
BY122X G5 LED200S SIA H4
BY122X G5 LED250S SIA H4
BY122X G5 LED300S SIA H4
Dimensions in mm
L
Suspension Mounting
1 1
Keep sensor protection
foam during installation
4441 702 64571
© 06/2022 Signify Holding B.V. All rights reserved
220V
50Hz
240V
60Hz
Class I
System
Optics
CCT(K)
lumen(lm)
10500
20000
4000
WB/NB
25000
30000
Accessory
Bracket
911401633208
BY121Z G5 BR L200
1. Luminaire should be parallel to the
floor, should not exceed < 2 °.
2. For communication between
luminaires, this would NOT allow a
luminaire to luminaire distance to be
greater than 10 meters.
3.Don't touch the sensor when you
mount luminaires.
36
2x
2 2
3Nm
GLOW
50 C
IP65
WIRE
650°
-30C
Dimension in mm
Pmax (W)
L
68
530
133
530
166
530
203
530
180
46
36
D>144
1/6
Max.
LIFE
D
50K hrs
Min.
@L85
W
H
393
5.3
99
393
99
5.3
126
393
6.6
393
126
6.6
Safety string
Suspension
Pipe
911401501071
911401633308
BY570Z Pipe
BY121Z G5 MB-SW
1. Safetey string has to be mounted
for this luminaire.
2.Safety string is not provided by
Signify, need to be prepared by user.
3. Material spec of safety string
should be robust and not less than
SUS304 Ø3.
G1/2
4.String length:d~d+30cm.
3
Included
Printed in China
Data subjectto change without notice
Keep for future reference: www.lighting.philips.com
30
IK05
light source energy
efficiencyclass
C
C
C
C

Publicité

loading

Sommaire des Matières pour Philips CoreLine Highbay Gen 5 BY122X

  • Page 1 SUS304 Ø3. mount luminaires. G1/2 4.String length:d~d+30cm. Suspension Mounting D>144 Keep sensor protection foam during installation Included Printed in China 4441 702 64571 Data subjectto change without notice © 06/2022 Signify Holding B.V. All rights reserved Keep for future reference: www.lighting.philips.com...
  • Page 2 Optional:Pipe Mounting Group Alignment(for sensor direction) 25Nm 25Nm G1/2 Unit:mm Optional:Bracket Mounting 30Nm M6 Screw D6 Spring washer G½ Screw D6 washer D20 tooth washer 25Nm Connect Power Cable 连接电源线 Inrush current BY120P BY121P BY122P I mains (A) BY122X BY122X BY122X BY122X I max...
  • Page 3 Top View Sensor far away from heat source > 2m Sensor far away from air outlet Disclaimer: 1. In these plots, the white areas are blind spots and the detection is based on subject’s motion. An idle subject Position (m) Side View may not continue to trigger occupancy detection once the hold time expires.
  • Page 4 GB - Disconnect before servicing DK - Frakobl, før service IT - Toglieretensioneprima di fare manutencione FR - Mettrehors tension avantintervention NO - Koble fra før service ES - Desconectarantes de manipular DE - Offnennurspannungsfrei FI - Irrota pistoke ennen huoltoa SE - Brytströmmenförelampbyte NL - Stroom afsluiten voor onderhoud CZ - P ed servisem se odpojte...
  • Page 5 Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty.
  • Page 6 Ürünlerin saklanması, kurulumu, kullanımı, çalı tırılması ve bakımı, ürünün kullanım ömrü boyunca güvenli kullanımının sa lanması amacıyla tam olarak bu kılavuzdaki ve / veya tarafımızdan sa lanan di er talimatlara uygun biçimde gerçekle tirilmelidir. Söz konusu talimatlara uyulmaması, ürünle ilgili garanti hakkınızı...