Télécharger Imprimer la page

Nordcap TMV-C14 Mode D'emploi page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
The warnings and safety instructions in this manual do not cover all possible conditions and situations that may occur, therefore
it is the user's responsibility to use the appliance with common sense, paying the utmost attention and care during installation,
maintenance and operation.
Since these instructions cover various product models, the characteristics of the purchased product may differ slightly from the
ones described in this manual. Maximum surface weight load 15 kg. A-weighted sound level is under 70 dB.
3. INSTALLATION
The unit is delivered in carton boxes on wood pallets. During transport and handling do not remove the product from its
packaging and use a mechanically operated device to move it. To handle the unit in order to place it (after removing the package),
it must be handled by holding the lower base. Gloves are mandatory.
If you have purchased the Parete Vino, please proceed with the installation as indicated in the "Installation instructions"
delivered together with the unit. The Teca is a product for free installation therefore do not require special assembly operations.
For correct operation the unit should be placed in a place free of excessive moisture, well-ventilated and away from sources of
heat, the ambient has to be with temperatures between 5 ° C and 30 ° C, avoiding exposure to direct sunlight, keeping it clean
from dust or other sediments.
Any damage caused by failure of following these recommendations is not covered by the guarantee and is not in any way the
manufacturer's responsibility.
It is also recommended to place the appliance so it can be used under NORMAL lighting conditions(defined as 200 LUX) E.D.
2006/42/EECE
Place the display on a even and flat surface, if needed regulate the four front and rear leveling feet to get a perfect level.
Important for its correct functioning and to allow the doors to close properly it is essential that it is perfectly level.
The installation and any maintenance operation on the equipment must be performed by a qualified technician or a service center.
Never connect the plug to an ungrounded socket and always check that its grounding is conform to the applicable local rules.
Do not install the appliance in a place subject to gas leaks.
When moving, in order to prevent damage to the floor, make sure the leveling feet are raised.
The display should not be placed outside or exposed to direct sunlight.
Once placed in the final position, leave the showcase turned off at least 4 hours, this reduces the possibility of malfunction of the
refrigerating system due to transport and handling.
• Insert the plug into the wall socket (see electrical system safety)
• To start operating the appliance act on the main switch located under the display on the right side (TECA) or on the front
lower side (PARETE - MOD)
• Turn on the display by pressing the power button of the controller (
• Let the machine run empty for at least two hours before inserting bottles / food
• At the beginning the unit might be noisy; gradually, letting the machine run, the noise will decrease
• The compressor will start automatically after a few minutes, if the unit is turned off and immediately turned on again or when
setting temperature, the compressor stops and starts automatically after a few minutes
• To connect the lights of the top unit "B" of the Parete Vino, connect the cables and bring the excess of the cable into the
technical tank of the lower unit "A".
The central refrigeration system with which the unit is equipped (5.3) works with a ventilated condensation system. The
ventilation - meaning the hot air expulsion and the suck of the fresh ambient air - is carried out in the lower part of the display,
exactly in the space where the 8 cm feet are installed. IT IS STRICTLY FORBIDDEN TO CLOSE OR OBSTRUCT THIS SPACE.
Not following the above instruction, not only creates a significant increase of consumption but can lead to serious malfunction or
accident and is considered as improper use, faulty installation or tampering and therefore will INVALIDATE THE PRODUCT WARRANTY.
The upper unit (P * -VBR10) needs a greater space to ensure sufficient air circulation.
Failure to comply with the above suggestion could affect the good operation of the unit and increase the electric consumption.
The showcase must be installed in order to allow easy movement for maintenance and cleaning operations.
The back side of the refrigerated unit must be placed at least 10 mm from the wall.
DO NOT CLOSE THE 8 CM (3,15 IN) SPACE UNDERNEATH THE BASE.
ALSO THE PARTIAL CLOSURE WITH INHIBIT THE VENTILATION.
FAILURE TO COMPLY THESE INSTRUCTIONS INVALIDATE THE WARRANTY.
LEAVE THIS SPACE FREE
) (see legend of key symbols)
CAUTION
LEAVE THIS SPACE FREE
11

Publicité

loading

Ce manuel est également adapté pour:

446114003