Télécharger Imprimer la page

ULTIMATE SPEED 435917 2304 Consignes D'utilisation Et De Sécurité / Traduction Du Mode D'emploi D'origine page 18

Publicité

Les langues disponibles

Les langues disponibles

Step
2. First connect
the red clamp (A)
to the positive
pole of the
vehicle battery
and then connect
the black battery
clamp (B) to the
negative pole
(see Fig. 1).
3. Starting up the
vehicle.
18
GB/IE/NI
LEDs
Red Error LED
on
13
the jump lead
is
10
permanently lit. A
short alarm will
sound twice a
second.
Red Error LED
on
13
the jump lead
is
10
permanently lit.
An alarm will sound
several times a
second in quick
succession.
Green Start LED
12
permanently lit.
Once the green Start
LED
has remained
12
permanently lit for
more than
90 seconds, then the
red Error LED
and
13
green Start LED
12
will be permanently
lit.
on
Red Error LED
13
the jump lead
is
10
permanently lit.
A short alarm will
sound once a
second.
Red Error LED
and
13
green Start LED
12
are permanently lit.
Meaning / Error
Battery clamps (A)
and (B) are the
wrong way round.
A short circuit has
occurred or the
battery is leaking.
The connection is
is
correct
The connection is
correct, however
because the vehicle
was not started
within 90 seconds,
the jump start
procedure was
stopped for safety
reasons.
The temperature is
too high, possibly
due to several jump
start attempts.
The starting
procedure has
failed.
The starting
procedure was
successful.
Solution
Disconnect
the black
battery
clamp (B)
first and
then the
red clamp
(A) from
the battery
poles. Start
again from
step 1.
Carry on
with step 3.
Disconnect
the black
battery
clamp (B)
first and
then the
red clamp
(A) from
the battery
poles. Start
again from
step 1.
Disconnect
the black
battery
clamp (B)
first and
then the
red clamp
(A) from
the battery
poles. Start
again from
step 1.
The motor is
running.

Publicité