Locate the ice cube thickness adjustment dial on the control board (see
Figure 30). Turn the dial clockwise (+ number) or counterclockwise
(- number) to thin the ice bridge.
Figure 30
DIAL IS
FACTORY
SET AT "0"
ICE CUBE THICKNESS
ADJUSTMENT DIAL
IMPOR
IMPORT T T T T ANT
IMPOR
IMPOR
IMPOR
Ice thickness adjustment dial can be rotated 1/4 to 1/2 turn on the number dial. Allow the
ice maker to stabilize for 24 hours before making further adjustments. Since ice cubes
in any given batch will vary, choose cubes from the sample area for comparison when
making adjustments (see Figure 31). The factory setting is 0.
Ice Cube Mold
SAMPLE AREA
Figure 31
ANT
ANT
ANT
ANT
4
Reinstall the front access cover.
5
Reconnect power to icemaker.