9.3.
Manual Cycle
Pressing any key from the main page (stand by), it is possible to access to the Manual/Automatic menu, to move
press the up and down arrows if needed.
Confirm the "Manual/Autom." Option with the "enter"key. The following operations can be performed:
Recovery
Vacuum
Leak Test
New oil injection
Gas Charging
NOTE: Additive Function not present.
Note
to perform the vacuum it is necessary that the a/c system does not contain gas;
To perform the oil injection and the gas recharge it is necessary that the system is vacuumed (perform the
vacuum before);
9.3.1 Gas charging for a pressured system:
See paragraph number 9.2
9.3.2 Menu "Manual/Autom"
Recovery Function:
Move (using arrow keys) on the icon "R" and press "Enter". The Station will recover the gas from the vehicle
system.
Recovery will stop automatically once the vehicle a/c system is completely free from Freon (pressures lower than
0.2 bar). The recovery procedure can be stopped whenever is needed just pressing "C/E" key.
The recovery will stop automatically when the a/c system is empty (with no gas inside pressure < 0,2bar). You can
stop the recovery phase anytime by pressing the key "C/E".
Once the "Recovery" is finished, the Station will start the Oil Drain phase. The vacuum pump is activated in this
phase.
At the end of the oil discharge phase (or if the recovery phase is interrupted), on the display the message "print
report?" will appear. Pressing "enter" it is possible to print out the latest operation (only Printer version), if you do
not need to print it, press "C/E".
14/04/2016
Oil Drain
Vers. 2
37